aus+uk / uk.comp.homebuilt / Re: warning: "This [Crucial M.2] storage device is likely to fail soon"

SubjectAuthor
* warning: "This [Crucial M.2] storage device is likely to fail soon"jkn
`* Re: warning: "This [Crucial M.2] storage device is likely to fail soon"Theo
 `* Re: warning: "This [Crucial M.2] storage device is likely to fail soon"jkn
  `* Re: warning: "This [Crucial M.2] storage device is likely to fail soon"Theo
   `* Re: warning: "This [Crucial M.2] storage device is likely to fail soon"Theo
    `- Re: warning: "This [Crucial M.2] storage device is likely to fail soon"jkn

1
warning: "This [Crucial M.2] storage device is likely to fail soon"

<805b4387-bcb2-43f4-8d43-4c5aea55cca5n@googlegroups.com>

  copy mid

https://www.novabbs.com/aus+uk/article-flat.php?id=2148&group=uk.comp.homebuilt#2148

  copy link   Newsgroups: uk.comp.homebuilt
X-Received: by 2002:a05:622a:95:b0:2f1:fa51:be58 with SMTP id o21-20020a05622a009500b002f1fa51be58mr21755969qtw.564.1651135570247;
Thu, 28 Apr 2022 01:46:10 -0700 (PDT)
X-Received: by 2002:a5b:50f:0:b0:629:5d05:aebf with SMTP id
o15-20020a5b050f000000b006295d05aebfmr29841561ybp.618.1651135570051; Thu, 28
Apr 2022 01:46:10 -0700 (PDT)
Path: i2pn2.org!i2pn.org!aioe.org!news.uzoreto.com!news-out.netnews.com!news.alt.net!fdc2.netnews.com!peer01.ams1!peer.ams1.xlned.com!news.xlned.com!peer01.iad!feed-me.highwinds-media.com!news.highwinds-media.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: uk.comp.homebuilt
Date: Thu, 28 Apr 2022 01:46:09 -0700 (PDT)
Injection-Info: google-groups.googlegroups.com; posting-host=84.92.96.37; posting-account=xy4V0QkAAAAoGgkMsSsv6bfFPHkQXvOY
NNTP-Posting-Host: 84.92.96.37
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <805b4387-bcb2-43f4-8d43-4c5aea55cca5n@googlegroups.com>
Subject: warning: "This [Crucial M.2] storage device is likely to fail soon"
From: jkn...@nicorp.f9.co.uk (jkn)
Injection-Date: Thu, 28 Apr 2022 08:46:10 +0000
Content-Type: text/plain; charset="UTF-8"
X-Received-Bytes: 5151
 by: jkn - Thu, 28 Apr 2022 08:46 UTC

Hi all
Just yesterday I upgraded my main desktop from Kubuntu 20.04 to 22.04 LTS. All went pretty well ... except this morning when I powered it up I got a worrying desktop warning message along the lines of:

The Storage Device /dev/nvme0n1 is likely to fail soon

erk!

I have not seen this before, but TBH yesterday was the first time I have powered this machine off in a long time; I'm checking 'quiescent' household power consumption.

I did a quick "sudo smartctl /dev/nvme0n1 -a" which doesn't look too bad, although I haven't delved deep. See below for the output.

So a few thoughts:

- any idea if this is related to my recent upgrade? ie. new feature in [K]Ubunto 22.04?
- is this likely to be a real issue, or an over-zealous warning?

I am thinking of doing two things: buying a new/larger(1TB) M.2 drive, and dd'ing everything over; and upgrading the firmware on this Crucial M.2 drive

- Is it a particularly risky operation up update the M.2 firmware without backing up the drive first?

Thanks for any thoughts
Jon N

{{{ output from: sudo smartctl /dev/nvme0n1 -a
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.0-27-generic] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Number: CT500P2SSD8
Serial Number: 2043E4BD82DC
Firmware Version: P2CR010
PCI Vendor/Subsystem ID: 0xc0a9
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 500,107,862,016 [500 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 500,107,862,016 [500 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 fff0000000
Local Time is: Thu Apr 28 09:39:36 2022 BST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x001f): Security Format Frmw_DL NS_Mngmt Self_Test
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 70 Celsius
Critical Comp. Temp. Threshold: 85 Celsius

Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0020W - - 4 4 4 4 5000 55000

Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0

=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 39 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 1,140,109 [583 GB]
Data Units Written: 2,357,594 [1.20 TB]
Host Read Commands: 14,832,947
Host Write Commands: 25,228,486
Controller Busy Time: 11,685
Power Cycles: 236
Power On Hours: 8,833
Unsafe Shutdowns: 38
Media and Data Integrity Errors: 0
Error Information Log Entries: 275
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0

Error Information (NVMe Log 0x01, 16 of 16 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS
0 275 0 0x1008 0x4005 0x028 0 0 -
}}}

Re: warning: "This [Crucial M.2] storage device is likely to fail soon"

<PJg*AAPMy@news.chiark.greenend.org.uk>

  copy mid

https://www.novabbs.com/aus+uk/article-flat.php?id=2149&group=uk.comp.homebuilt#2149

  copy link   Newsgroups: uk.comp.homebuilt
Path: i2pn2.org!i2pn.org!aioe.org!nntp.terraraq.uk!nntp-feed.chiark.greenend.org.uk!ewrotcd!.POSTED!not-for-mail
From: theom+n...@chiark.greenend.org.uk (Theo)
Newsgroups: uk.comp.homebuilt
Subject: Re: warning: "This [Crucial M.2] storage device is likely to fail soon"
Date: 28 Apr 2022 10:12:09 +0100 (BST)
Organization: University of Cambridge, England
Lines: 44
Message-ID: <PJg*AAPMy@news.chiark.greenend.org.uk>
References: <805b4387-bcb2-43f4-8d43-4c5aea55cca5n@googlegroups.com>
NNTP-Posting-Host: chiark.greenend.org.uk
X-Trace: chiark.greenend.org.uk 1651137131 8873 212.13.197.229 (28 Apr 2022 09:12:11 GMT)
X-Complaints-To: abuse@chiark.greenend.org.uk
NNTP-Posting-Date: Thu, 28 Apr 2022 09:12:11 +0000 (UTC)
User-Agent: tin/1.8.3-20070201 ("Scotasay") (UNIX) (Linux/3.16.0-11-amd64 (x86_64))
Originator: theom@chiark.greenend.org.uk ([212.13.197.229])
 by: Theo - Thu, 28 Apr 2022 09:12 UTC

jkn <jkn_gg@nicorp.f9.co.uk> wrote:
> So a few thoughts:
>
> - any idea if this is related to my recent upgrade? ie. new feature in [K]Ubunto 22.04?
> - is this likely to be a real issue, or an over-zealous warning?

I checked my NVMe and I don't have an 'error log' section. I don't know
what yours means. You could try nvme-cli (that's the package in Ubuntu) eg:

$ sudo nvme error-log /dev/nvme0n1
$ sudo nvme smart-log /dev/nvme0n1
(other *-log commands available)

and see if it reports anything interesting. eg for me smart-log says:

$ sudo nvme smart-log /dev/nvme1n1
Smart Log for NVME device:nvme1n1 namespace-id:ffffffff
critical_warning : 0
temperature : 25 C
available_spare : 100%
available_spare_threshold : 5%
percentage_used : 10%
endurance group critical warning summary: 0

so I seem to have used 10% of my write endurance (I think).

It is possible doing an upgrade has eaten some of your available writes and
pushed it over some threshold.

> I am thinking of doing two things: buying a new/larger(1TB) M.2 drive, and
> dd'ing everything over; and upgrading the firmware on this Crucial M.2
> drive
>
> - Is it a particularly risky operation up update the M.2 firmware without backing up the drive first?

In theory it shouldn't be a risk to update the firmware (it happens in
production all the time), but if the drive is exhibiting failure signs I'd
want to make a backup first just in case.

Theo

(who hadn't come across nvme-cli before and thinks it could be a useful way
of using cheaper NVMe in servers and replacing drives when they start
running out of writes)

Re: warning: "This [Crucial M.2] storage device is likely to fail soon"

<66ccb25a-c2d5-45c7-9957-a5e2234ad622n@googlegroups.com>

  copy mid

https://www.novabbs.com/aus+uk/article-flat.php?id=2150&group=uk.comp.homebuilt#2150

  copy link   Newsgroups: uk.comp.homebuilt
X-Received: by 2002:a0c:b3cf:0:b0:456:4e1b:8da4 with SMTP id b15-20020a0cb3cf000000b004564e1b8da4mr6643847qvf.86.1651137845316;
Thu, 28 Apr 2022 02:24:05 -0700 (PDT)
X-Received: by 2002:a0d:ff05:0:b0:2ea:25ed:d714 with SMTP id
p5-20020a0dff05000000b002ea25edd714mr32078931ywf.454.1651137845173; Thu, 28
Apr 2022 02:24:05 -0700 (PDT)
Path: i2pn2.org!i2pn.org!weretis.net!feeder8.news.weretis.net!border2.nntp.dca1.giganews.com!nntp.giganews.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: uk.comp.homebuilt
Date: Thu, 28 Apr 2022 02:24:04 -0700 (PDT)
In-Reply-To: <PJg*AAPMy@news.chiark.greenend.org.uk>
Injection-Info: google-groups.googlegroups.com; posting-host=84.92.96.37; posting-account=xy4V0QkAAAAoGgkMsSsv6bfFPHkQXvOY
NNTP-Posting-Host: 84.92.96.37
References: <805b4387-bcb2-43f4-8d43-4c5aea55cca5n@googlegroups.com> <PJg*AAPMy@news.chiark.greenend.org.uk>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <66ccb25a-c2d5-45c7-9957-a5e2234ad622n@googlegroups.com>
Subject: Re: warning: "This [Crucial M.2] storage device is likely to fail soon"
From: jkn...@nicorp.f9.co.uk (jkn)
Injection-Date: Thu, 28 Apr 2022 09:24:05 +0000
Content-Type: text/plain; charset="UTF-8"
Lines: 105
 by: jkn - Thu, 28 Apr 2022 09:24 UTC

On Thursday, April 28, 2022 at 10:12:12 AM UTC+1, Theo wrote:
> jkn <jkn...@nicorp.f9.co.uk> wrote:
> > So a few thoughts:
> >
> > - any idea if this is related to my recent upgrade? ie. new feature in [K]Ubunto 22.04?
> > - is this likely to be a real issue, or an over-zealous warning?
> I checked my NVMe and I don't have an 'error log' section. I don't know
> what yours means. You could try nvme-cli (that's the package in Ubuntu) eg:
>
> $ sudo nvme error-log /dev/nvme0n1
> $ sudo nvme smart-log /dev/nvme0n1
> (other *-log commands available)
>
> and see if it reports anything interesting. eg for me smart-log says:
>
> $ sudo nvme smart-log /dev/nvme1n1
> Smart Log for NVME device:nvme1n1 namespace-id:ffffffff
> critical_warning : 0
> temperature : 25 C
> available_spare : 100%
> available_spare_threshold : 5%
> percentage_used : 10%
> endurance group critical warning summary: 0
>
> so I seem to have used 10% of my write endurance (I think).
>
> It is possible doing an upgrade has eaten some of your available writes and
> pushed it over some threshold.
> > I am thinking of doing two things: buying a new/larger(1TB) M.2 drive, and
> > dd'ing everything over; and upgrading the firmware on this Crucial M.2
> > drive
> >
> > - Is it a particularly risky operation up update the M.2 firmware without backing up the drive first?
> In theory it shouldn't be a risk to update the firmware (it happens in
> production all the time), but if the drive is exhibiting failure signs I'd
> want to make a backup first just in case.
>
> Theo
>
> (who hadn't come across nvme-cli before and thinks it could be a useful way
> of using cheaper NVMe in servers and replacing drives when they start
> running out of writes)

Thanks a lot Theo, very useful.
I installed nvme-cli and get this:

{{{ $ sudo nvme error-log /dev/nvme0n1
Error Log Entries for device:nvme0n1 entries:16
..................
Entry[ 0]
..................
error_count : 275
sqid : 0
cmdid : 0x1008
status_field : 0x2002(INVALID_FIELD: A reserved coded value or an unsupported value in a defined field)
phase_tag : 0x1
parm_err_loc : 0x28
lba : 0
nsid : 0
vs : 0
trtype : The transport type is not indicated or the error is not transport related.
cs : 0
trtype_spec_info: 0

# (all other log entries seem 'empty')
}}}

{{{ $ sudo nvme smart-log /dev/nvme0n1
Smart Log for NVME device:nvme0n1 namespace-id:ffffffff
critical_warning : 0
temperature : 31 C (304 Kelvin)
available_spare : 100%
available_spare_threshold : 5%
percentage_used : 0%
endurance group critical warning summary: 0
data_units_read : 1,140,151
data_units_written : 2,357,758
host_read_commands : 14,833,879
host_write_commands : 25,231,374
controller_busy_time : 11,687
power_cycles : 236
power_on_hours : 8,834
unsafe_shutdowns : 38
media_errors : 0
num_err_log_entries : 275
Warning Temperature Time : 0
Critical Composite Temperature Time : 0
Thermal Management T1 Trans Count : 0
Thermal Management T2 Trans Count : 0
Thermal Management T1 Total Time : 0
Thermal Management T2 Total Time : 0
}}}

> It is possible doing an upgrade has eaten some of your available writes and
> pushed it over some threshold.

That is a good thought...

I think I will press on with buying a new 1TB M.2 drive (I was thinking of doing
that anyway, as it happens), and updating the firmware on this one
only after I have dd'd everything over and swapped to the new one.

Any recommendations for a decent M.2 1TB drive? I see a lot of slagging off
on Amazon on the Crucial P2 I have here...

Thanks, J^n

Re: warning: "This [Crucial M.2] storage device is likely to fail soon"

<OJg*7OPMy@news.chiark.greenend.org.uk>

  copy mid

https://www.novabbs.com/aus+uk/article-flat.php?id=2151&group=uk.comp.homebuilt#2151

  copy link   Newsgroups: uk.comp.homebuilt
Path: i2pn2.org!i2pn.org!news.nntp4.net!nntp.terraraq.uk!nntp-feed.chiark.greenend.org.uk!ewrotcd!.POSTED!not-for-mail
From: theom+n...@chiark.greenend.org.uk (Theo)
Newsgroups: uk.comp.homebuilt
Subject: Re: warning: "This [Crucial M.2] storage device is likely to fail soon"
Date: 28 Apr 2022 11:14:04 +0100 (BST)
Organization: University of Cambridge, England
Lines: 23
Message-ID: <OJg*7OPMy@news.chiark.greenend.org.uk>
References: <805b4387-bcb2-43f4-8d43-4c5aea55cca5n@googlegroups.com> <PJg*AAPMy@news.chiark.greenend.org.uk> <66ccb25a-c2d5-45c7-9957-a5e2234ad622n@googlegroups.com>
NNTP-Posting-Host: chiark.greenend.org.uk
X-Trace: chiark.greenend.org.uk 1651140846 20774 212.13.197.229 (28 Apr 2022 10:14:06 GMT)
X-Complaints-To: abuse@chiark.greenend.org.uk
NNTP-Posting-Date: Thu, 28 Apr 2022 10:14:06 +0000 (UTC)
User-Agent: tin/1.8.3-20070201 ("Scotasay") (UNIX) (Linux/3.16.0-11-amd64 (x86_64))
Originator: theom@chiark.greenend.org.uk ([212.13.197.229])
 by: Theo - Thu, 28 Apr 2022 10:14 UTC

jkn <jkn_gg@nicorp.f9.co.uk> wrote:
> I think I will press on with buying a new 1TB M.2 drive (I was thinking of
> doing that anyway, as it happens), and updating the firmware on this one
> only after I have dd'd everything over and swapped to the new one.

Sounds reasonable.

> Any recommendations for a decent M.2 1TB drive? I see a lot of slagging off
> on Amazon on the Crucial P2 I have here...

Samsung Evo are my standard fit. I've also been using Sabrent as they have
been better at producing PCIe Gen4 drives at a decent price, although I'm a
bit more uncertain about reliability. (I have 8 of them in a server,
everything is fine thus far...)

I would avoid QLC drives (cheap but slow, sometimes HDD-slow). TLC isn't a
great deal more expensive.

Previously I would have aimed for an SSD with DRAM rather than a DRAM-less
one but they seem to be harder to find these days. DRAMless is probably
fine unless you're serving databases or similar.

Theo

Re: warning: "This [Crucial M.2] storage device is likely to fail soon"

<RJg*xTPMy@news.chiark.greenend.org.uk>

  copy mid

https://www.novabbs.com/aus+uk/article-flat.php?id=2152&group=uk.comp.homebuilt#2152

  copy link   Newsgroups: uk.comp.homebuilt
Path: i2pn2.org!i2pn.org!news.nntp4.net!nntp.terraraq.uk!nntp-feed.chiark.greenend.org.uk!ewrotcd!.POSTED!not-for-mail
From: theom+n...@chiark.greenend.org.uk (Theo)
Newsgroups: uk.comp.homebuilt
Subject: Re: warning: "This [Crucial M.2] storage device is likely to fail soon"
Date: 28 Apr 2022 11:33:03 +0100 (BST)
Organization: University of Cambridge, England
Lines: 24
Message-ID: <RJg*xTPMy@news.chiark.greenend.org.uk>
References: <805b4387-bcb2-43f4-8d43-4c5aea55cca5n@googlegroups.com> <PJg*AAPMy@news.chiark.greenend.org.uk> <66ccb25a-c2d5-45c7-9957-a5e2234ad622n@googlegroups.com> <OJg*7OPMy@news.chiark.greenend.org.uk>
NNTP-Posting-Host: chiark.greenend.org.uk
X-Trace: chiark.greenend.org.uk 1651141985 20774 212.13.197.229 (28 Apr 2022 10:33:05 GMT)
X-Complaints-To: abuse@chiark.greenend.org.uk
NNTP-Posting-Date: Thu, 28 Apr 2022 10:33:05 +0000 (UTC)
User-Agent: tin/1.8.3-20070201 ("Scotasay") (UNIX) (Linux/3.16.0-11-amd64 (x86_64))
Originator: theom@chiark.greenend.org.uk ([212.13.197.229])
 by: Theo - Thu, 28 Apr 2022 10:33 UTC

Theo <theom+news@chiark.greenend.org.uk> wrote:
> Previously I would have aimed for an SSD with DRAM rather than a DRAM-less
> one but they seem to be harder to find these days. DRAMless is probably
> fine unless you're serving databases or similar.

One other thing... if it's going to be under any kind of intense workload
(eg compiling) what I tend to do is look for 'performance consistency'
graphs, eg this is a cheap and old drive:

https://www.anandtech.com/show/9258/crucial-mx200-250gb-500gb-1tb-ssd-review/2

You can see the IOPS fall off a cliff once the buffer cache is exhausted.

One way to improve this is to leave some portion of the drive unwritten - eg
partition it to 900GB not 1TB and leave the last 100GB as unwritten blocks.
This gives the drive a bit more breathing space as it can have more spare
blocks to play with. Anandtech's benchmarks sometimes incorporate such
overprovisioning, eg:
https://www.anandtech.com/show/9451/the-2tb-samsung-850-pro-evo-ssd-review/2

You probably don't care about performance to that level but it's something I
look at when selecting drives.

Theo

Re: warning: "This [Crucial M.2] storage device is likely to fail soon"

<afd0f771-b67f-43e8-895a-dec42edbea74n@googlegroups.com>

  copy mid

https://www.novabbs.com/aus+uk/article-flat.php?id=2153&group=uk.comp.homebuilt#2153

  copy link   Newsgroups: uk.comp.homebuilt
X-Received: by 2002:ac8:5f09:0:b0:2f3:7005:6f58 with SMTP id x9-20020ac85f09000000b002f370056f58mr11582837qta.439.1651144055146;
Thu, 28 Apr 2022 04:07:35 -0700 (PDT)
X-Received: by 2002:a5b:107:0:b0:648:a9c3:445a with SMTP id
7-20020a5b0107000000b00648a9c3445amr10938053ybx.571.1651144054968; Thu, 28
Apr 2022 04:07:34 -0700 (PDT)
Path: i2pn2.org!i2pn.org!weretis.net!feeder6.news.weretis.net!nntp.club.cc.cmu.edu!144.202.29.153.MISMATCH!1.us.feeder.erje.net!feeder.erje.net!border1.nntp.dca1.giganews.com!nntp.giganews.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: uk.comp.homebuilt
Date: Thu, 28 Apr 2022 04:07:34 -0700 (PDT)
In-Reply-To: <RJg*xTPMy@news.chiark.greenend.org.uk>
Injection-Info: google-groups.googlegroups.com; posting-host=84.92.96.37; posting-account=xy4V0QkAAAAoGgkMsSsv6bfFPHkQXvOY
NNTP-Posting-Host: 84.92.96.37
References: <805b4387-bcb2-43f4-8d43-4c5aea55cca5n@googlegroups.com>
<PJg*AAPMy@news.chiark.greenend.org.uk> <66ccb25a-c2d5-45c7-9957-a5e2234ad622n@googlegroups.com>
<OJg*7OPMy@news.chiark.greenend.org.uk> <RJg*xTPMy@news.chiark.greenend.org.uk>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <afd0f771-b67f-43e8-895a-dec42edbea74n@googlegroups.com>
Subject: Re: warning: "This [Crucial M.2] storage device is likely to fail soon"
From: jkn...@nicorp.f9.co.uk (jkn)
Injection-Date: Thu, 28 Apr 2022 11:07:35 +0000
Content-Type: text/plain; charset="UTF-8"
Lines: 33
 by: jkn - Thu, 28 Apr 2022 11:07 UTC

On Thursday, April 28, 2022 at 11:33:07 AM UTC+1, Theo wrote:
> Theo <theom...@chiark.greenend.org.uk> wrote:
> > Previously I would have aimed for an SSD with DRAM rather than a DRAM-less
> > one but they seem to be harder to find these days. DRAMless is probably
> > fine unless you're serving databases or similar.
> One other thing... if it's going to be under any kind of intense workload
> (eg compiling) what I tend to do is look for 'performance consistency'
> graphs, eg this is a cheap and old drive:
>
> https://www.anandtech.com/show/9258/crucial-mx200-250gb-500gb-1tb-ssd-review/2
>
> You can see the IOPS fall off a cliff once the buffer cache is exhausted.
>
> One way to improve this is to leave some portion of the drive unwritten - eg
> partition it to 900GB not 1TB and leave the last 100GB as unwritten blocks.
> This gives the drive a bit more breathing space as it can have more spare
> blocks to play with. Anandtech's benchmarks sometimes incorporate such
> overprovisioning, eg:
> https://www.anandtech.com/show/9451/the-2tb-samsung-850-pro-evo-ssd-review/2
>
> You probably don't care about performance to that level but it's something I
> look at when selecting drives.
>
> Theo
Thanks Theo, that's all very useful. I do do some semi-intensive compiling so
the point is well taken.

As it happens I've just placed an order for a Samsung 970 EVO Plus (1TB),
I will take your advice and leave some part unpartitioned.

Anyone suggest any semi-decent NVME USB-C enclosures to move my
Crucial P2 drive to once I have updated the firmware etc?

Thanks again, Jon N