computers / comp.os.vms / Re: 'Partitioning' raid controller for VMS on Integrity

SubjectAuthor
* 'Partitioning' raid controller for VMS on IntegrityRich Jordan
+* Re: 'Partitioning' raid controller for VMS on IntegrityDave Froble
|`* Re: 'Partitioning' raid controller for VMS on IntegrityArne Vajhøj
| `* Re: 'Partitioning' raid controller for VMS on Integritydthi...@gmail.com
|  `- Re: 'Partitioning' raid controller for VMS on Integritydthi...@gmail.com
+* Re: 'Partitioning' raid controller for VMS on IntegrityBob Gezelter
|+- Re: 'Partitioning' raid controller for VMS on IntegrityPhillip Helbig (undress to reply
|+- Re: 'Partitioning' raid controller for VMS on Integrityhb
|`- Re: 'Partitioning' raid controller for VMS on IntegritySimon Clubley
+* Re: 'Partitioning' raid controller for VMS on IntegrityStephen Hoffman
|`* Re: 'Partitioning' raid controller for VMS on IntegrityRich Jordan
| `* Re: 'Partitioning' raid controller for VMS on IntegrityDave Froble
|  `* Re: 'Partitioning' raid controller for VMS on Integrityabrsvc
|   `* Re: 'Partitioning' raid controller for VMS on IntegrityRich Jordan
|    `* Re: 'Partitioning' raid controller for VMS on IntegrityRich Jordan
|     `* Re: 'Partitioning' raid controller for VMS on IntegrityDuncanMorris
|      `* Re: 'Partitioning' raid controller for VMS on IntegrityRich Jordan
|       `* Re: 'Partitioning' raid controller for VMS on IntegrityRich Jordan
|        `- Re: 'Partitioning' raid controller for VMS on IntegrityLawrence D’Oliveiro
+- Re: 'Partitioning' raid controller for VMS on IntegrityDavid Turner
`- Re: 'Partitioning' raid controller for VMS on Integritychris

1
'Partitioning' raid controller for VMS on Integrity

<847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16789&group=comp.os.vms#16789

  copy link   Newsgroups: comp.os.vms
X-Received: by 2002:a0c:cd86:: with SMTP id v6mr199344qvm.26.1631145971128;
Wed, 08 Sep 2021 17:06:11 -0700 (PDT)
X-Received: by 2002:a05:620a:9c9:: with SMTP id y9mr252977qky.207.1631145970858;
Wed, 08 Sep 2021 17:06:10 -0700 (PDT)
Path: i2pn2.org!i2pn.org!weretis.net!feeder6.news.weretis.net!news.misty.com!border2.nntp.dca1.giganews.com!nntp.giganews.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: comp.os.vms
Date: Wed, 8 Sep 2021 17:06:10 -0700 (PDT)
Injection-Info: google-groups.googlegroups.com; posting-host=162.251.133.98; posting-account=-m1l1AkAAAAOcQipwxcZ5ncqqoxN3l1E
NNTP-Posting-Host: 162.251.133.98
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
Subject: 'Partitioning' raid controller for VMS on Integrity
From: jor...@ccs4vms.com (Rich Jordan)
Injection-Date: Thu, 09 Sep 2021 00:06:11 +0000
Content-Type: text/plain; charset="UTF-8"
Lines: 4
 by: Rich Jordan - Thu, 9 Sep 2021 00:06 UTC

VMS doesn't do partitions. Are there any SAS type RAID controllers for RX servers that can present 'partitioned' logical drives to VMS so it sees separate spindles?

Wondering if it is possible at all to f/ex build a 4 disk ADG array and present more than one spindle to VMS from it.

Thanks

Re: 'Partitioning' raid controller for VMS on Integrity

<shbls0$2sh$1@dont-email.me>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16790&group=comp.os.vms#16790

  copy link   Newsgroups: comp.os.vms
Path: i2pn2.org!i2pn.org!eternal-september.org!reader02.eternal-september.org!.POSTED!not-for-mail
From: dav...@tsoft-inc.com (Dave Froble)
Newsgroups: comp.os.vms
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
Date: Wed, 8 Sep 2021 20:49:30 -0400
Organization: A noiseless patient Spider
Lines: 19
Message-ID: <shbls0$2sh$1@dont-email.me>
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
Mime-Version: 1.0
Content-Type: text/plain; charset=utf-8; format=flowed
Content-Transfer-Encoding: 7bit
Injection-Date: Thu, 9 Sep 2021 00:52:16 -0000 (UTC)
Injection-Info: reader02.eternal-september.org; posting-host="2edd33369de59b454887faf99e35b057";
logging-data="2961"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX1/3YN5mjHHWdvJ+XMHu+cFxCAx3Hs6UROk="
User-Agent: Mozilla/5.0 (Windows NT 5.1; rv:45.0) Gecko/20100101
Thunderbird/45.8.0
Cancel-Lock: sha1:RHvPeZUKty4/WdtLgAV3s5nI8Es=
In-Reply-To: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
 by: Dave Froble - Thu, 9 Sep 2021 00:49 UTC

On 9/8/2021 8:06 PM, Rich Jordan wrote:
> VMS doesn't do partitions. Are there any SAS type RAID controllers for RX servers that can present 'partitioned' logical drives to VMS so it sees separate spindles?
>
> Wondering if it is possible at all to f/ex build a 4 disk ADG array and present more than one spindle to VMS from it.
>
> Thanks
>

There may have been times when partitions were needed. But not today,
as I see it. What possible advantage might there be for partitions
today? It is still a single disk, and lose it, you lose all the
partitions on it.

--
David Froble Tel: 724-529-0450
Dave Froble Enterprises, Inc. E-Mail: davef@tsoft-inc.com
DFE Ultralights, Inc.
170 Grimplin Road
Vanderbilt, PA 15486

Re: 'Partitioning' raid controller for VMS on Integrity

<shbmks$1b2e$1@gioia.aioe.org>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16791&group=comp.os.vms#16791

  copy link   Newsgroups: comp.os.vms
Path: i2pn2.org!i2pn.org!aioe.org!LeVffQP25j5GAigzc2gaQA.user.46.165.242.75.POSTED!not-for-mail
From: arn...@vajhoej.dk (Arne Vajhøj)
Newsgroups: comp.os.vms
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
Date: Wed, 8 Sep 2021 21:05:28 -0400
Organization: Aioe.org NNTP Server
Message-ID: <shbmks$1b2e$1@gioia.aioe.org>
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
<shbls0$2sh$1@dont-email.me>
Mime-Version: 1.0
Content-Type: text/plain; charset=utf-8; format=flowed
Content-Transfer-Encoding: 8bit
Injection-Info: gioia.aioe.org; logging-data="44110"; posting-host="LeVffQP25j5GAigzc2gaQA.user.gioia.aioe.org"; mail-complaints-to="abuse@aioe.org";
User-Agent: Mozilla/5.0 (Windows NT 6.1; Win64; x64; rv:78.0) Gecko/20100101
Thunderbird/78.14.0
X-Notice: Filtered by postfilter v. 0.9.2
Content-Language: en-US
 by: Arne Vajhøj - Thu, 9 Sep 2021 01:05 UTC

On 9/8/2021 8:49 PM, Dave Froble wrote:
> On 9/8/2021 8:06 PM, Rich Jordan wrote:
>> VMS doesn't do partitions.  Are there any SAS type RAID controllers
>> for RX servers that can present 'partitioned' logical drives to VMS so
>> it sees separate spindles?
>>
>> Wondering if it is possible at all to f/ex build a 4 disk ADG array
>> and present more than one spindle to VMS from it.
>
> There may have been times when partitions were needed.  But not today,
> as I see it.  What possible advantage might there be for partitions
> today?  It is still a single disk, and lose it, you lose all the
> partitions on it.

Maybe to work around VMS max volume size limit?

Arne

Re: 'Partitioning' raid controller for VMS on Integrity

<8c720917-7148-4145-be05-45bab0da2a40n@googlegroups.com>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16792&group=comp.os.vms#16792

  copy link   Newsgroups: comp.os.vms
X-Received: by 2002:a05:6214:762:: with SMTP id f2mr452093qvz.48.1631150664834;
Wed, 08 Sep 2021 18:24:24 -0700 (PDT)
X-Received: by 2002:ac8:7118:: with SMTP id z24mr536859qto.281.1631150664572;
Wed, 08 Sep 2021 18:24:24 -0700 (PDT)
Path: i2pn2.org!i2pn.org!weretis.net!feeder6.news.weretis.net!news.misty.com!border2.nntp.dca1.giganews.com!nntp.giganews.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: comp.os.vms
Date: Wed, 8 Sep 2021 18:24:24 -0700 (PDT)
In-Reply-To: <shbmks$1b2e$1@gioia.aioe.org>
Injection-Info: google-groups.googlegroups.com; posting-host=184.59.100.14; posting-account=kZBiTgoAAADmAc60TO9Jm9WVg1drxCZ1
NNTP-Posting-Host: 184.59.100.14
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
<shbls0$2sh$1@dont-email.me> <shbmks$1b2e$1@gioia.aioe.org>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <8c720917-7148-4145-be05-45bab0da2a40n@googlegroups.com>
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
From: dthitt...@gmail.com (dthi...@gmail.com)
Injection-Date: Thu, 09 Sep 2021 01:24:24 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
Lines: 22
 by: dthi...@gmail.com - Thu, 9 Sep 2021 01:24 UTC

Yes, the P400 and P800 SAS controllers can RAID any or all the drives together, and then you can partition the RAIDset into multiple logical drives.

I do that on my Integrity 2660 and P800, With an ADG (RAID6) across 7 SAS drives, then cut it up into multiple logical drives (DKx0, DKx1, DKx2).

The built-in RAID firmware can create the first logical drive, but you need to use MSA$UTIL to create the rest of the logical drives. Or you can just boot OpenVMS from a flash drive, then use MSA$UTIL to erase and re-RAID and/or cut the RAIDset up into multiple logical drives.

David

On Wednesday, September 8, 2021 at 9:05:37 PM UTC-4, Arne Vajhøj wrote:
> On 9/8/2021 8:49 PM, Dave Froble wrote:
> > On 9/8/2021 8:06 PM, Rich Jordan wrote:
> >> VMS doesn't do partitions. Are there any SAS type RAID controllers
> >> for RX servers that can present 'partitioned' logical drives to VMS so
> >> it sees separate spindles?
> >>

Re: 'Partitioning' raid controller for VMS on Integrity

<fbb03b74-9e14-41c7-91a3-cf2d6011f766n@googlegroups.com>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16793&group=comp.os.vms#16793

  copy link   Newsgroups: comp.os.vms
X-Received: by 2002:ac8:4b43:: with SMTP id e3mr567519qts.312.1631150856297;
Wed, 08 Sep 2021 18:27:36 -0700 (PDT)
X-Received: by 2002:a0c:aa8d:: with SMTP id f13mr444406qvb.31.1631150856187;
Wed, 08 Sep 2021 18:27:36 -0700 (PDT)
Path: i2pn2.org!i2pn.org!weretis.net!feeder6.news.weretis.net!news.misty.com!border2.nntp.dca1.giganews.com!nntp.giganews.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: comp.os.vms
Date: Wed, 8 Sep 2021 18:27:36 -0700 (PDT)
In-Reply-To: <8c720917-7148-4145-be05-45bab0da2a40n@googlegroups.com>
Injection-Info: google-groups.googlegroups.com; posting-host=184.59.100.14; posting-account=kZBiTgoAAADmAc60TO9Jm9WVg1drxCZ1
NNTP-Posting-Host: 184.59.100.14
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
<shbls0$2sh$1@dont-email.me> <shbmks$1b2e$1@gioia.aioe.org> <8c720917-7148-4145-be05-45bab0da2a40n@googlegroups.com>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <fbb03b74-9e14-41c7-91a3-cf2d6011f766n@googlegroups.com>
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
From: dthitt...@gmail.com (dthi...@gmail.com)
Injection-Date: Thu, 09 Sep 2021 01:27:36 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
Lines: 21
 by: dthi...@gmail.com - Thu, 9 Sep 2021 01:27 UTC

I forgot to mention that you can do the same logical disk partitioning with SCSI on Integrity as well.

I have an rx2600 with a 6402 SCSI RAID controller, and have cut a large 7-drive RAIDset into DKx0, DKx1, and DKx2.

On Wednesday, September 8, 2021 at 9:24:26 PM UTC-4, dthi...@gmail.com wrote:
> Yes, the P400 and P800 SAS controllers can RAID any or all the drives together, and then you can partition the RAIDset into multiple logical drives.
>
> I do that on my Integrity 2660 and P800, With an ADG (RAID6) across 7 SAS drives, then cut it up into multiple logical drives (DKx0, DKx1, DKx2).
>
> The built-in RAID firmware can create the first logical drive, but you need to use MSA$UTIL to create the rest of the logical drives. Or you can just boot OpenVMS from a flash drive, then use MSA$UTIL to erase and re-RAID and/or cut the RAIDset up into multiple logical drives.
>
> David

Re: 'Partitioning' raid controller for VMS on Integrity

<4d714e26-1132-46f3-9b9b-2611bba2accfn@googlegroups.com>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16797&group=comp.os.vms#16797

  copy link   Newsgroups: comp.os.vms
X-Received: by 2002:a05:620a:d8e:: with SMTP id q14mr2424905qkl.409.1631190324649;
Thu, 09 Sep 2021 05:25:24 -0700 (PDT)
X-Received: by 2002:a05:622a:142:: with SMTP id v2mr2581249qtw.242.1631190324438;
Thu, 09 Sep 2021 05:25:24 -0700 (PDT)
Path: i2pn2.org!i2pn.org!weretis.net!feeder6.news.weretis.net!news.misty.com!border2.nntp.dca1.giganews.com!nntp.giganews.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: comp.os.vms
Date: Thu, 9 Sep 2021 05:25:24 -0700 (PDT)
In-Reply-To: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
Injection-Info: google-groups.googlegroups.com; posting-host=100.2.113.217; posting-account=r2_qcwoAAACbIdit5Eka3ivGvrYZz7UQ
NNTP-Posting-Host: 100.2.113.217
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <4d714e26-1132-46f3-9b9b-2611bba2accfn@googlegroups.com>
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
From: gezel...@rlgsc.com (Bob Gezelter)
Injection-Date: Thu, 09 Sep 2021 12:25:24 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
Lines: 47
 by: Bob Gezelter - Thu, 9 Sep 2021 12:25 UTC

On Wednesday, September 8, 2021 at 8:06:12 PM UTC-4, Rich Jordan wrote:
> VMS doesn't do partitions. Are there any SAS type RAID controllers for RX servers that can present 'partitioned' logical drives to VMS so it sees separate spindles?
>
> Wondering if it is possible at all to f/ex build a 4 disk ADG array and present more than one spindle to VMS from it.
>
> Thanks

Rich,
..
WADR, IMO the question is not "can a disk be partitioned", but rather, "Can a disk be divided logically with several different file systems?"

The answer is undoubtedly "Yes", on two different levels.

As has been mentioned earlier in this thread, the last several generations of external storage arrays have supported "logical volumes" which are storage BLOBs of indeterminate composition (non-RAID, RAID-0, RAID-1, ... ).

Outside the hardware space, OpenVMS has a are multiple choices within a volume and collections of volumes.

The original supra-volume solution was and is FILES-11 volume sets. Supported since the beginning, and still useful for a variety of purposes.

Host-based Volume Shadowing allows the creation of shadow-sets, including single volume shadow sets, which can be expanded dynamically for various purposes, e.g. volume changeover, volume expansion, and backup.

There is also the LD facility, which allows one to create virtual volumes within an overarching volume structure, which can be used to effectively "partition" a disk volume, e.g. create a logical disk, then make the file contiguous. I have used this "file system within a file system" to create disks with different cluster factors for different uses, e.g., one file system for sources, command files, and other user programs, with a relatively small cluster factor, side by side or within a file structure with a
cluster factor more attuned to large (multi-gigabyte) database or other files.

One can also play mix-and-match with the facilities in various ways, depending upon your goal.

Outside of the Hobbyist world, it is a good idea to document what was done, and more importantly WHY it was done.

- Bob Gezelter, http://www.rlgsc.com

Re: 'Partitioning' raid controller for VMS on Integrity

<shd0jj$1pa7$1@gioia.aioe.org>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16798&group=comp.os.vms#16798

  copy link   Newsgroups: comp.os.vms
Path: i2pn2.org!i2pn.org!aioe.org!cchSjpoNiu7yIfhio2s1JQ.user.46.165.242.75.POSTED!not-for-mail
From: hel...@asclothestro.multivax.de (Phillip Helbig (undress to reply)
Newsgroups: comp.os.vms
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
Date: Thu, 9 Sep 2021 13:01:39 -0000 (UTC)
Organization: Multivax C&R
Message-ID: <shd0jj$1pa7$1@gioia.aioe.org>
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com> <4d714e26-1132-46f3-9b9b-2611bba2accfn@googlegroups.com>
Mime-Version: 1.0
Content-Type: text/plain; charset=ISO-8859-15
Content-Transfer-Encoding: 8bit
Injection-Info: gioia.aioe.org; logging-data="58695"; posting-host="cchSjpoNiu7yIfhio2s1JQ.user.gioia.aioe.org"; mail-complaints-to="abuse@aioe.org";
X-Notice: Filtered by postfilter v. 0.9.2
 by: Phillip Helbig (undr - Thu, 9 Sep 2021 13:01 UTC

In article <4d714e26-1132-46f3-9b9b-2611bba2accfn@googlegroups.com>, Bob
Gezelter <gezelter@rlgsc.com> writes:

> Outside of the Hobbyist world, it is a good idea to document what was done,
> and more importantly WHY it was done.

Also a good idea in the hobbyist world. :-)

Re: 'Partitioning' raid controller for VMS on Integrity

<shd251$lt4$1@gioia.aioe.org>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16799&group=comp.os.vms#16799

  copy link   Newsgroups: comp.os.vms
Path: i2pn2.org!i2pn.org!aioe.org!HsVkLr1zbWC9cT20TLEn2Q.user.46.165.242.91.POSTED!not-for-mail
From: end...@inter.net (hb)
Newsgroups: comp.os.vms
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
Date: Thu, 9 Sep 2021 15:28:01 +0200
Organization: Aioe.org NNTP Server
Message-ID: <shd251$lt4$1@gioia.aioe.org>
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
<4d714e26-1132-46f3-9b9b-2611bba2accfn@googlegroups.com>
Mime-Version: 1.0
Content-Type: text/plain; charset=utf-8
Content-Transfer-Encoding: 8bit
Injection-Info: gioia.aioe.org; logging-data="22436"; posting-host="HsVkLr1zbWC9cT20TLEn2Q.user.gioia.aioe.org"; mail-complaints-to="abuse@aioe.org";
User-Agent: Mozilla/5.0 (X11; Linux x86_64; rv:78.0) Gecko/20100101
Thunderbird/78.13.0
X-Notice: Filtered by postfilter v. 0.9.2
Content-Language: en-US
 by: hb - Thu, 9 Sep 2021 13:28 UTC

On 9/9/21 2:25 PM, Bob Gezelter wrote:
> There is also the LD facility, which allows one to create virtual volumes within an overarching volume structure, which can be used to effectively "partition" a disk volume, e.g. create a logical disk, then make the file contiguous. I have used this "file system within a file system" to create disks ...

FWIW, $ ld help connect /lbn
....
/LBN=(START=x,END=y) or
/LBN=(START=X,COUNT=y)

Connect an LD device to a physical disk, starting at LBN x, with either
an end-lbn specified or a count. The ending lbn may not be beyond the
end of the physical device. The count plus the starting lbn may also
not be beyond the end. With this qualifier it is possible to partially
map a physical disk.

And yes, the VMS virtual disk driver, VD, could/can do this as well.

Re: 'Partitioning' raid controller for VMS on Integrity

<shdgvk$met$1@dont-email.me>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16800&group=comp.os.vms#16800

  copy link   Newsgroups: comp.os.vms
Path: i2pn2.org!i2pn.org!eternal-september.org!reader02.eternal-september.org!.POSTED!not-for-mail
From: club...@remove_me.eisner.decus.org-Earth.UFP (Simon Clubley)
Newsgroups: comp.os.vms
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
Date: Thu, 9 Sep 2021 17:41:08 -0000 (UTC)
Organization: A noiseless patient Spider
Lines: 32
Message-ID: <shdgvk$met$1@dont-email.me>
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com> <4d714e26-1132-46f3-9b9b-2611bba2accfn@googlegroups.com>
Injection-Date: Thu, 9 Sep 2021 17:41:08 -0000 (UTC)
Injection-Info: reader02.eternal-september.org; posting-host="9ddcb4fe9dd6d1a66d32d5e632c470bb";
logging-data="23005"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX185aG5KkFBHGs4wFudSZKnFMYHi8k3X6/U="
User-Agent: slrn/0.9.8.1 (VMS/Multinet)
Cancel-Lock: sha1:JJJrHmccsPFZ6tjJINnhcUXGnG8=
 by: Simon Clubley - Thu, 9 Sep 2021 17:41 UTC

On 2021-09-09, Bob Gezelter <gezelter@rlgsc.com> wrote:
>
> The original supra-volume solution was and is FILES-11 volume sets. Supported since the beginning, and still useful for a variety of purposes.
>
> Host-based Volume Shadowing allows the creation of shadow-sets, including single volume shadow sets, which can be expanded dynamically for various purposes, e.g. volume changeover, volume expansion, and backup.
>
> There is also the LD facility, which allows one to create virtual volumes within an overarching volume structure, which can be used to effectively "partition" a disk volume, e.g. create a logical disk, then make the file contiguous. I have used this "file system within a file system" to create disks with different cluster factors for different uses, e.g., one file system for sources, command files, and other user programs, with a relatively small cluster factor, side by side or within a file structure with a
> cluster factor more attuned to large (multi-gigabyte) database or other files.
>

Bob,

The VMS-hosted options you list above are all in the wrong direction
_if_ the goal is to make use of larger disk sizes than VMS supports.

What does actually happen if you try to initialise a (say) 8TB disk
with an ODS-2/ODS-5 filesystem ?

Do you get a disk is too big error message ?

Does VMS just use the first 2TB of the volume and ignore the rest ?

Does it try to create a 8TB filesystem anyway and then either hang or
create an invalid filesystem ?

I've never tried it so I don't know.

Simon.

--
Simon Clubley, clubley@remove_me.eisner.decus.org-Earth.UFP
Walking destinations on a map are further away than they appear.

Re: 'Partitioning' raid controller for VMS on Integrity

<shdok8$i1h$1@dont-email.me>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16805&group=comp.os.vms#16805

  copy link   Newsgroups: comp.os.vms
Path: i2pn2.org!i2pn.org!eternal-september.org!reader02.eternal-september.org!.POSTED!not-for-mail
From: seaoh...@hoffmanlabs.invalid (Stephen Hoffman)
Newsgroups: comp.os.vms
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
Date: Thu, 9 Sep 2021 15:51:36 -0400
Organization: HoffmanLabs LLC
Lines: 30
Message-ID: <shdok8$i1h$1@dont-email.me>
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
Mime-Version: 1.0
Content-Type: text/plain; charset=iso-8859-1; format=flowed
Content-Transfer-Encoding: 8bit
Injection-Info: reader02.eternal-september.org; posting-host="1b0b040ee099d9ccec67e544aec58db3";
logging-data="18481"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX1+4o6+Mq5j36LJ1OG2nDHAvCAXSusZla3s="
User-Agent: Unison/2.2
Cancel-Lock: sha1:YHN//0dudPjx+VOIV3ggowrV/0g=
 by: Stephen Hoffman - Thu, 9 Sep 2021 19:51 UTC

On 2021-09-09 00:06:10 +0000, Rich Jordan said:

> VMS doesn't do partitions. Are there any SAS type RAID controllers for
> RX servers that can present 'partitioned' logical drives to VMS so it
> sees separate spindles?
>
> Wondering if it is possible at all to f/ex build a 4 disk ADG array and
> present more than one spindle to VMS from it.

Recent array controllers can do this (logical drives distributed across
one or more arrays of physical devices), though the HP/HPE
documentation here seemed lacking.

Among these, P410 and P812, and others.

You'll probably be using MSA$UTIL to establish this, and/or one of the
HP/HPE tools.

Getting disks in and out of the RAIDset can sometimes be a little
tricky to manage when a failure arises. Best to get extra HDDs or SSDs,
and pre- provision some into the arrays as spares.

http://h10032.www1.hp.com/ctg/Manual/c02289065.pdf

etc.

--
Pure Personal Opinion | HoffmanLabs LLC

Re: 'Partitioning' raid controller for VMS on Integrity

<15c70f35-155d-45d7-8bb9-933b8a042507n@googlegroups.com>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16810&group=comp.os.vms#16810

  copy link   Newsgroups: comp.os.vms
X-Received: by 2002:ac8:405b:: with SMTP id j27mr5671122qtl.101.1631231309314;
Thu, 09 Sep 2021 16:48:29 -0700 (PDT)
X-Received: by 2002:a05:620a:2215:: with SMTP id m21mr5158477qkh.86.1631231308844;
Thu, 09 Sep 2021 16:48:28 -0700 (PDT)
Path: i2pn2.org!i2pn.org!weretis.net!feeder6.news.weretis.net!news.misty.com!border2.nntp.dca1.giganews.com!nntp.giganews.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: comp.os.vms
Date: Thu, 9 Sep 2021 16:48:28 -0700 (PDT)
In-Reply-To: <shdok8$i1h$1@dont-email.me>
Injection-Info: google-groups.googlegroups.com; posting-host=162.251.133.98; posting-account=-m1l1AkAAAAOcQipwxcZ5ncqqoxN3l1E
NNTP-Posting-Host: 162.251.133.98
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com> <shdok8$i1h$1@dont-email.me>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <15c70f35-155d-45d7-8bb9-933b8a042507n@googlegroups.com>
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
From: jor...@ccs4vms.com (Rich Jordan)
Injection-Date: Thu, 09 Sep 2021 23:48:29 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
Lines: 69
 by: Rich Jordan - Thu, 9 Sep 2021 23:48 UTC

On Thursday, September 9, 2021 at 2:51:39 PM UTC-5, Stephen Hoffman wrote:
> On 2021-09-09 00:06:10 +0000, Rich Jordan said:
>
> > VMS doesn't do partitions. Are there any SAS type RAID controllers for
> > RX servers that can present 'partitioned' logical drives to VMS so it
> > sees separate spindles?
> >
> > Wondering if it is possible at all to f/ex build a 4 disk ADG array and
> > present more than one spindle to VMS from it.
> Recent array controllers can do this (logical drives distributed across
> one or more arrays of physical devices), though the HP/HPE
> documentation here seemed lacking.
>
> Among these, P410 and P812, and others.
>
> You'll probably be using MSA$UTIL to establish this, and/or one of the
> HP/HPE tools.
>
> Getting disks in and out of the RAIDset can sometimes be a little
> tricky to manage when a failure arises. Best to get extra HDDs or SSDs,
> and pre- provision some into the arrays as spares.
>
> http://h10032.www1.hp.com/ctg/Manual/c02289065.pdf
>
> etc.
>
>
> --
> Pure Personal Opinion | HoffmanLabs LLC

Thanks to all who responded. The older system has 18 drives providing nine mirrored volumes, plus another 6 mirrored 'universal' drives proving backup staging space. They are hoping that we can put in an RX-2800 with eight larger SAS drives (which even RAID'ed will add up to much more space) but due to the age and complexity of the software involved we really want to keep the same number of spindles/volumes visible to VMS. If possible without a second controller and more drives in a shelf. If we have to merge more than one or two disks together it will seriously increase the complexity of acceptance testing; everything should be clearly controlled via logicals but a lot of hands wrote a lot of software over 30+ years, so dropping to four large mirrorsets is not going to happen. I know we can do the work, but the time and cost...

We have an RX2660 we use for testing here; it has a P410i with the advanced license and some 1.2TB SAS drives (and four smaller ones). I can make an ADG array with the four large drives in ORCA, but it does not provide any means of 'breaking that down' into smaller volumes to pass to VMS. I tried (once, so maybe missed something) to use MSA$UTIL from the DVD boot of HP VMS V8.4, and it also doesn't seem to have options to break down that large disk (which is already visible to VMS). So if a P410 can do this (is a P410i different in that regard?) I should be able to test on the 2660 and confirm that it can be done on the potential RX-2800.

I'm installing VMS kit on a local disk temporarily so I can see if the MSA$UTIL options are different when booting from a live disk. I've got the appropriate update kits available to install

If SAUPDATE from the UEFI console is also capable of doing the volume setups then I'm going to try to find that kit/download somewhere; HPe moved it all behind paywalls. I should have RX2620 firmware kits from when ours was under support but I doubt I have that for the 2660 (which was a customer letting us have it back when they retired); no idea if we could use one kit for just that one utility on a different box.

Thanks again

Re: 'Partitioning' raid controller for VMS on Integrity

<shecbh$6th$1@dont-email.me>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16814&group=comp.os.vms#16814

  copy link   Newsgroups: comp.os.vms
Path: i2pn2.org!i2pn.org!eternal-september.org!reader02.eternal-september.org!.POSTED!not-for-mail
From: dav...@tsoft-inc.com (Dave Froble)
Newsgroups: comp.os.vms
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
Date: Thu, 9 Sep 2021 21:25:53 -0400
Organization: A noiseless patient Spider
Lines: 41
Message-ID: <shecbh$6th$1@dont-email.me>
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
<shdok8$i1h$1@dont-email.me>
<15c70f35-155d-45d7-8bb9-933b8a042507n@googlegroups.com>
Mime-Version: 1.0
Content-Type: text/plain; charset=utf-8; format=flowed
Content-Transfer-Encoding: 7bit
Injection-Date: Fri, 10 Sep 2021 01:28:17 -0000 (UTC)
Injection-Info: reader02.eternal-september.org; posting-host="89dbe85338d12e55cdc2884d22cc5276";
logging-data="7089"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX1+wo9kYtOM8zIQEVGweX+wqvJcmHlTTmw4="
User-Agent: Mozilla/5.0 (Windows NT 5.1; rv:45.0) Gecko/20100101
Thunderbird/45.8.0
Cancel-Lock: sha1:5vU/Lzxvw11Cj49zFK1+trUzQYk=
In-Reply-To: <15c70f35-155d-45d7-8bb9-933b8a042507n@googlegroups.com>
 by: Dave Froble - Fri, 10 Sep 2021 01:25 UTC

On 9/9/2021 7:48 PM, Rich Jordan wrote:

> Thanks to all who responded. The older system has 18 drives providing nine mirrored volumes, plus another 6 mirrored 'universal' drives proving backup staging space. They are hoping that we can put in an RX-2800 with eight larger SAS drives (which even RAID'ed will add up to much more space) but due to the age and complexity of the software involved we really want to keep the same number of spindles/volumes visible to VMS. If possible without a second controller and more drives in a shelf. If we have to merge more than one or two disks together it will seriously increase the complexity of acceptance testing; everything should be clearly controlled via logicals but a lot of hands wrote a lot of software over 30+ years, so dropping to four large mirrorsets is not going to happen. I know we can do the work, but the time and cost...
>
> We have an RX2660 we use for testing here; it has a P410i with the advanced license and some 1.2TB SAS drives (and four smaller ones). I can make an ADG array with the four large drives in ORCA, but it does not provide any means of 'breaking that down' into smaller volumes to pass to VMS. I tried (once, so maybe missed something) to use MSA$UTIL from the DVD boot of HP VMS V8.4, and it also doesn't seem to have options to break down that large disk (which is already visible to VMS). So if a P410 can do this (is a P410i different in that regard?) I should be able to test on the 2660 and confirm that it can be done on the potential RX-2800.
>
> I'm installing VMS kit on a local disk temporarily so I can see if the MSA$UTIL options are different when booting from a live disk. I've got the appropriate update kits available to install
>
> If SAUPDATE from the UEFI console is also capable of doing the volume setups then I'm going to try to find that kit/download somewhere; HPe moved it all behind paywalls. I should have RX2620 firmware kits from when ours was under support but I doubt I have that for the 2660 (which was a customer letting us have it back when they retired); no idea if we could use one kit for just that one utility on a different box.
>
> Thanks again
>

I don't know how your system(s) are configured, so this may not be helpful.

We use those "dratted logicals" to define disks. So we can move things
around, just with the logicals.

Say:

Disk0
Disk1
Disk2
Disk3

Are current. However if we wanted to replace both Disk2 and Disk3 with
one larger disk, all we would do is to have both logical names Disk2 and
Disk3 both point to the new larger disk.

There could still be issues. Say the old disks have identical directory
names that are used for different purposes. Or other unknown to me issues.

If you're not using logical names in a like manner, then perhaps your
solutions will be a bit more difficult.

--
David Froble Tel: 724-529-0450
Dave Froble Enterprises, Inc. E-Mail: davef@tsoft-inc.com
DFE Ultralights, Inc.
170 Grimplin Road
Vanderbilt, PA 15486

Re: 'Partitioning' raid controller for VMS on Integrity

<28d7ee6c-9789-4471-af7c-d089c57dc4d8n@googlegroups.com>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16820&group=comp.os.vms#16820

  copy link   Newsgroups: comp.os.vms
X-Received: by 2002:ad4:5541:: with SMTP id v1mr7609162qvy.49.1631270932148;
Fri, 10 Sep 2021 03:48:52 -0700 (PDT)
X-Received: by 2002:a37:aa8f:: with SMTP id t137mr6921965qke.30.1631270932008;
Fri, 10 Sep 2021 03:48:52 -0700 (PDT)
Path: i2pn2.org!i2pn.org!weretis.net!feeder6.news.weretis.net!news.misty.com!border2.nntp.dca1.giganews.com!nntp.giganews.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: comp.os.vms
Date: Fri, 10 Sep 2021 03:48:51 -0700 (PDT)
In-Reply-To: <shecbh$6th$1@dont-email.me>
Injection-Info: google-groups.googlegroups.com; posting-host=96.230.211.194; posting-account=Ysq9BAoAAACGX1EcMMPkdNg4YcTg0TxG
NNTP-Posting-Host: 96.230.211.194
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
<shdok8$i1h$1@dont-email.me> <15c70f35-155d-45d7-8bb9-933b8a042507n@googlegroups.com>
<shecbh$6th$1@dont-email.me>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <28d7ee6c-9789-4471-af7c-d089c57dc4d8n@googlegroups.com>
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
From: dansabrs...@yahoo.com (abrsvc)
Injection-Date: Fri, 10 Sep 2021 10:48:52 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
Lines: 74
 by: abrsvc - Fri, 10 Sep 2021 10:48 UTC

On Thursday, September 9, 2021 at 9:28:21 PM UTC-4, Dave Froble wrote:
> On 9/9/2021 7:48 PM, Rich Jordan wrote:
>
> > Thanks to all who responded. The older system has 18 drives providing nine mirrored volumes, plus another 6 mirrored 'universal' drives proving backup staging space. They are hoping that we can put in an RX-2800 with eight larger SAS drives (which even RAID'ed will add up to much more space) but due to the age and complexity of the software involved we really want to keep the same number of spindles/volumes visible to VMS. If possible without a second controller and more drives in a shelf. If we have to merge more than one or two disks together it will seriously increase the complexity of acceptance testing; everything should be clearly controlled via logicals but a lot of hands wrote a lot of software over 30+ years, so dropping to four large mirrorsets is not going to happen. I know we can do the work, but the time and cost...
> >
> > We have an RX2660 we use for testing here; it has a P410i with the advanced license and some 1.2TB SAS drives (and four smaller ones). I can make an ADG array with the four large drives in ORCA, but it does not provide any means of 'breaking that down' into smaller volumes to pass to VMS. I tried (once, so maybe missed something) to use MSA$UTIL from the DVD boot of HP VMS V8.4, and it also doesn't seem to have options to break down that large disk (which is already visible to VMS). So if a P410 can do this (is a P410i different in that regard?) I should be able to test on the 2660 and confirm that it can be done on the potential RX-2800.
> >
> > I'm installing VMS kit on a local disk temporarily so I can see if the MSA$UTIL options are different when booting from a live disk. I've got the appropriate update kits available to install
> >
> > If SAUPDATE from the UEFI console is also capable of doing the volume setups then I'm going to try to find that kit/download somewhere; HPe moved it all behind paywalls. I should have RX2620 firmware kits from when ours was under support but I doubt I have that for the 2660 (which was a customer letting us have it back when they retired); no idea if we could use one kit for just that one utility on a different box.
> >
> > Thanks again
> >
> I don't know how your system(s) are configured, so this may not be helpful.
>
> We use those "dratted logicals" to define disks. So we can move things
> around, just with the logicals.
>
> Say:
>
> Disk0
> Disk1
> Disk2
> Disk3
>
> Are current. However if we wanted to replace both Disk2 and Disk3 with
> one larger disk, all we would do is to have both logical names Disk2 and
> Disk3 both point to the new larger disk.
>
> There could still be issues. Say the old disks have identical directory
> names that are used for different purposes. Or other unknown to me issues..
>
> If you're not using logical names in a like manner, then perhaps your
> solutions will be a bit more difficult.
> --
> David Froble Tel: 724-529-0450
> Dave Froble Enterprises, Inc. E-Mail: da...@tsoft-inc.com
> DFE Ultralights, Inc.
> 170 Grimplin Road
> Vanderbilt, PA 15486

The use of concealed devices can "fix" this too. I have successfully used these to accomplish having multiple "disks" on a single one.

Dan

Re: 'Partitioning' raid controller for VMS on Integrity

<3613a2ce-b9e5-454e-a916-1143ec4706ean@googlegroups.com>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16824&group=comp.os.vms#16824

  copy link   Newsgroups: comp.os.vms
X-Received: by 2002:a05:620a:4001:: with SMTP id h1mr8020886qko.454.1631283994690;
Fri, 10 Sep 2021 07:26:34 -0700 (PDT)
X-Received: by 2002:ac8:1404:: with SMTP id k4mr8120487qtj.278.1631283994525;
Fri, 10 Sep 2021 07:26:34 -0700 (PDT)
Path: i2pn2.org!i2pn.org!weretis.net!feeder6.news.weretis.net!news.misty.com!border2.nntp.dca1.giganews.com!nntp.giganews.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: comp.os.vms
Date: Fri, 10 Sep 2021 07:26:34 -0700 (PDT)
In-Reply-To: <28d7ee6c-9789-4471-af7c-d089c57dc4d8n@googlegroups.com>
Injection-Info: google-groups.googlegroups.com; posting-host=162.251.133.98; posting-account=-m1l1AkAAAAOcQipwxcZ5ncqqoxN3l1E
NNTP-Posting-Host: 162.251.133.98
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
<shdok8$i1h$1@dont-email.me> <15c70f35-155d-45d7-8bb9-933b8a042507n@googlegroups.com>
<shecbh$6th$1@dont-email.me> <28d7ee6c-9789-4471-af7c-d089c57dc4d8n@googlegroups.com>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <3613a2ce-b9e5-454e-a916-1143ec4706ean@googlegroups.com>
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
From: jor...@ccs4vms.com (Rich Jordan)
Injection-Date: Fri, 10 Sep 2021 14:26:34 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
Lines: 102
 by: Rich Jordan - Fri, 10 Sep 2021 14:26 UTC

On Friday, September 10, 2021 at 5:48:53 AM UTC-5, abrsvc wrote:
> On Thursday, September 9, 2021 at 9:28:21 PM UTC-4, Dave Froble wrote:
> > On 9/9/2021 7:48 PM, Rich Jordan wrote:
> >
> > > Thanks to all who responded. The older system has 18 drives providing nine mirrored volumes, plus another 6 mirrored 'universal' drives proving backup staging space. They are hoping that we can put in an RX-2800 with eight larger SAS drives (which even RAID'ed will add up to much more space) but due to the age and complexity of the software involved we really want to keep the same number of spindles/volumes visible to VMS. If possible without a second controller and more drives in a shelf. If we have to merge more than one or two disks together it will seriously increase the complexity of acceptance testing; everything should be clearly controlled via logicals but a lot of hands wrote a lot of software over 30+ years, so dropping to four large mirrorsets is not going to happen. I know we can do the work, but the time and cost...
> > >
> > > We have an RX2660 we use for testing here; it has a P410i with the advanced license and some 1.2TB SAS drives (and four smaller ones). I can make an ADG array with the four large drives in ORCA, but it does not provide any means of 'breaking that down' into smaller volumes to pass to VMS. I tried (once, so maybe missed something) to use MSA$UTIL from the DVD boot of HP VMS V8.4, and it also doesn't seem to have options to break down that large disk (which is already visible to VMS). So if a P410 can do this (is a P410i different in that regard?) I should be able to test on the 2660 and confirm that it can be done on the potential RX-2800.
> > >
> > > I'm installing VMS kit on a local disk temporarily so I can see if the MSA$UTIL options are different when booting from a live disk. I've got the appropriate update kits available to install
> > >
> > > If SAUPDATE from the UEFI console is also capable of doing the volume setups then I'm going to try to find that kit/download somewhere; HPe moved it all behind paywalls. I should have RX2620 firmware kits from when ours was under support but I doubt I have that for the 2660 (which was a customer letting us have it back when they retired); no idea if we could use one kit for just that one utility on a different box.
> > >
> > > Thanks again
> > >
> > I don't know how your system(s) are configured, so this may not be helpful.
> >
> > We use those "dratted logicals" to define disks. So we can move things
> > around, just with the logicals.
> >
> > Say:
> >
> > Disk0
> > Disk1
> > Disk2
> > Disk3
> >
> > Are current. However if we wanted to replace both Disk2 and Disk3 with
> > one larger disk, all we would do is to have both logical names Disk2 and
> > Disk3 both point to the new larger disk.
> >
> > There could still be issues. Say the old disks have identical directory
> > names that are used for different purposes. Or other unknown to me issues.
> >
> > If you're not using logical names in a like manner, then perhaps your
> > solutions will be a bit more difficult.
> > --
> > David Froble Tel: 724-529-0450
> > Dave Froble Enterprises, Inc. E-Mail: da...@tsoft-inc.com
> > DFE Ultralights, Inc.
> > 170 Grimplin Road
> > Vanderbilt, PA 15486
> The use of concealed devices can "fix" this too. I have successfully used these to accomplish having multiple "disks" on a single one.
>
> Dan

The system was designed with logicals. The devs over the years were supposed to use said logicals, and the last major system change 10 or so years go rooted out the mistakes when the Integrity disks had different names (for which we also used concealed logicals). However we want to avoid going through the effort needed to merge multiple current disks together onto fewer larger ones. Yes, there are overlaps in the directory structures between the drives. Old stuff, moved stuff, archived stuff, and the devs are not at all or barely available for questions.

This is not an issue about overall disk size (other than getting more space, easy since the largest current spindle is 300GB mirrorset). If we 1.5x the size of every current disk (way more than enough given past growth) the seven data drives will still fit the 2.4TB 4 drive ADG that I set up on the test box.

But we really want at least 7 spindles (8 or 9 better) with RAID protection without doing an external shelf and a whole other set of disks. Paritioning at the controller level would do that.

We'll find out if msa$util from installed VMS (as opposed to DVD boot) can do something with the P410i in that regard. I can wipe and rebuild the ADG array for any testing.

Rich

Re: 'Partitioning' raid controller for VMS on Integrity

<672dnXjupNbn76b8nZ2dnUU7-eWdnZ2d@supernews.com>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16826&group=comp.os.vms#16826

  copy link   Newsgroups: comp.os.vms
Path: i2pn2.org!i2pn.org!weretis.net!feeder6.news.weretis.net!news.misty.com!border2.nntp.dca1.giganews.com!nntp.giganews.com!buffer2.nntp.dca1.giganews.com!nntp.supernews.com!news.supernews.com.POSTED!not-for-mail
NNTP-Posting-Date: Fri, 10 Sep 2021 09:58:02 -0500
Reply-To: dturner@islandco.com
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
Newsgroups: comp.os.vms
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
From: dtur...@islandco.com (David Turner)
Organization: Island Computers
Date: Fri, 10 Sep 2021 10:58:00 -0400
User-Agent: Mozilla/5.0 (Windows NT 10.0; Win64; x64; rv:78.0) Gecko/20100101
Thunderbird/78.13.0
MIME-Version: 1.0
In-Reply-To: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
Content-Type: text/plain; charset=utf-8; format=flowed
Content-Transfer-Encoding: 7bit
Content-Language: en-US
Message-ID: <672dnXjupNbn76b8nZ2dnUU7-eWdnZ2d@supernews.com>
Lines: 20
X-Trace: sv3-4r1c9Sll44B9sro/VxuSwrcnszXyi6bsqL+u1TnWrp6j7xNtkFnvZ1nCDAMQjqS67i4Arkk1qrk71GA!mbiVeYgCbCIyR/bFnDYhtZ6+YTQaHtl5B1IaacSUivKtjZ2EtVQ+XU2LxYN4OLS0r3xkpbtU/sje!ITgb8dua+MPzZA==
X-Complaints-To: www.supernews.com/docs/abuse.html
X-DMCA-Complaints-To: www.supernews.com/docs/dmca.html
X-Abuse-and-DMCA-Info: Please be sure to forward a copy of ALL headers
X-Abuse-and-DMCA-Info: Otherwise we will be unable to process your complaint properly
X-Postfilter: 1.3.40
X-Original-Bytes: 2034
 by: David Turner - Fri, 10 Sep 2021 14:58 UTC

For what it's worth, I have several customers now who have gone the the
P2000 external RAID arrays
They look kinda like the D2700 shelf except the have the option modules
for SAS, Fiber, ISCSI or all three
I know you can partition disks on these
Great web based user interface too. Easiest external box I have ever set up

We stock them of course...

David

On 9/8/2021 8:06 PM, Rich Jordan wrote:
> VMS doesn't do partitions. Are there any SAS type RAID controllers for RX servers that can present 'partitioned' logical drives to VMS so it sees separate spindles?
>
> Wondering if it is possible at all to f/ex build a 4 disk ADG array and present more than one spindle to VMS from it.
>
> Thanks

Re: 'Partitioning' raid controller for VMS on Integrity

<fe9d5d8e-fdf7-4a2b-9ab2-fad957d240efn@googlegroups.com>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16915&group=comp.os.vms#16915

  copy link   Newsgroups: comp.os.vms
X-Received: by 2002:a0c:8bc9:: with SMTP id a9mr2084535qvc.29.1631574450867;
Mon, 13 Sep 2021 16:07:30 -0700 (PDT)
X-Received: by 2002:ae9:e609:: with SMTP id z9mr2132548qkf.222.1631574450697;
Mon, 13 Sep 2021 16:07:30 -0700 (PDT)
Path: i2pn2.org!i2pn.org!weretis.net!feeder6.news.weretis.net!news.misty.com!border2.nntp.dca1.giganews.com!nntp.giganews.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: comp.os.vms
Date: Mon, 13 Sep 2021 16:07:30 -0700 (PDT)
In-Reply-To: <3613a2ce-b9e5-454e-a916-1143ec4706ean@googlegroups.com>
Injection-Info: google-groups.googlegroups.com; posting-host=162.251.133.98; posting-account=-m1l1AkAAAAOcQipwxcZ5ncqqoxN3l1E
NNTP-Posting-Host: 162.251.133.98
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
<shdok8$i1h$1@dont-email.me> <15c70f35-155d-45d7-8bb9-933b8a042507n@googlegroups.com>
<shecbh$6th$1@dont-email.me> <28d7ee6c-9789-4471-af7c-d089c57dc4d8n@googlegroups.com>
<3613a2ce-b9e5-454e-a916-1143ec4706ean@googlegroups.com>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <fe9d5d8e-fdf7-4a2b-9ab2-fad957d240efn@googlegroups.com>
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
From: jor...@ccs4vms.com (Rich Jordan)
Injection-Date: Mon, 13 Sep 2021 23:07:30 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
Lines: 123
 by: Rich Jordan - Mon, 13 Sep 2021 23:07 UTC

On Friday, September 10, 2021 at 9:26:35 AM UTC-5, Rich Jordan wrote:
> On Friday, September 10, 2021 at 5:48:53 AM UTC-5, abrsvc wrote:
> > On Thursday, September 9, 2021 at 9:28:21 PM UTC-4, Dave Froble wrote:
> > > On 9/9/2021 7:48 PM, Rich Jordan wrote:
> > >
> > > > Thanks to all who responded. The older system has 18 drives providing nine mirrored volumes, plus another 6 mirrored 'universal' drives proving backup staging space. They are hoping that we can put in an RX-2800 with eight larger SAS drives (which even RAID'ed will add up to much more space) but due to the age and complexity of the software involved we really want to keep the same number of spindles/volumes visible to VMS. If possible without a second controller and more drives in a shelf. If we have to merge more than one or two disks together it will seriously increase the complexity of acceptance testing; everything should be clearly controlled via logicals but a lot of hands wrote a lot of software over 30+ years, so dropping to four large mirrorsets is not going to happen. I know we can do the work, but the time and cost...
> > > >
> > > > We have an RX2660 we use for testing here; it has a P410i with the advanced license and some 1.2TB SAS drives (and four smaller ones). I can make an ADG array with the four large drives in ORCA, but it does not provide any means of 'breaking that down' into smaller volumes to pass to VMS. I tried (once, so maybe missed something) to use MSA$UTIL from the DVD boot of HP VMS V8.4, and it also doesn't seem to have options to break down that large disk (which is already visible to VMS). So if a P410 can do this (is a P410i different in that regard?) I should be able to test on the 2660 and confirm that it can be done on the potential RX-2800.
> > > >
> > > > I'm installing VMS kit on a local disk temporarily so I can see if the MSA$UTIL options are different when booting from a live disk. I've got the appropriate update kits available to install
> > > >
> > > > If SAUPDATE from the UEFI console is also capable of doing the volume setups then I'm going to try to find that kit/download somewhere; HPe moved it all behind paywalls. I should have RX2620 firmware kits from when ours was under support but I doubt I have that for the 2660 (which was a customer letting us have it back when they retired); no idea if we could use one kit for just that one utility on a different box.
> > > >
> > > > Thanks again
> > > >
> > > I don't know how your system(s) are configured, so this may not be helpful.
> > >
> > > We use those "dratted logicals" to define disks. So we can move things
> > > around, just with the logicals.
> > >
> > > Say:
> > >
> > > Disk0
> > > Disk1
> > > Disk2
> > > Disk3
> > >
> > > Are current. However if we wanted to replace both Disk2 and Disk3 with
> > > one larger disk, all we would do is to have both logical names Disk2 and
> > > Disk3 both point to the new larger disk.
> > >
> > > There could still be issues. Say the old disks have identical directory
> > > names that are used for different purposes. Or other unknown to me issues.
> > >
> > > If you're not using logical names in a like manner, then perhaps your
> > > solutions will be a bit more difficult.
> > > --
> > > David Froble Tel: 724-529-0450
> > > Dave Froble Enterprises, Inc. E-Mail: da...@tsoft-inc.com
> > > DFE Ultralights, Inc.
> > > 170 Grimplin Road
> > > Vanderbilt, PA 15486
> > The use of concealed devices can "fix" this too. I have successfully used these to accomplish having multiple "disks" on a single one.
> >
> > Dan
> The system was designed with logicals. The devs over the years were supposed to use said logicals, and the last major system change 10 or so years go rooted out the mistakes when the Integrity disks had different names (for which we also used concealed logicals). However we want to avoid going through the effort needed to merge multiple current disks together onto fewer larger ones. Yes, there are overlaps in the directory structures between the drives. Old stuff, moved stuff, archived stuff, and the devs are not at all or barely available for questions.
>
> This is not an issue about overall disk size (other than getting more space, easy since the largest current spindle is 300GB mirrorset). If we 1.5x the size of every current disk (way more than enough given past growth) the seven data drives will still fit the 2.4TB 4 drive ADG that I set up on the test box.
>
> But we really want at least 7 spindles (8 or 9 better) with RAID protection without doing an external shelf and a whole other set of disks. Paritioning at the controller level would do that.
>
> We'll find out if msa$util from installed VMS (as opposed to DVD boot) can do something with the P410i in that regard. I can wipe and rebuild the ADG array for any testing.
>
> Rich

And the results are in unless there's super secret MSA$UTIL commands that I don't have docs for. No go. The P410i apparently does not provide any means of generating individual disks that are a subset of a single RAID logical disk. Whether its a single disk or a mirror pair, or a RAID set with multiple disks, only the single unit is provided to VMS.

We're going to look at the second controller and drive shelf to get 8 spindles; that will be enough to get by without major work. Hate losing the optical drive for that but that can be worked around.

Interestingly... the 2660 has a SCSI Card in it for use with a tape library; it is the same card that I understand was spec'd for the RX-2800s. I hooked an external disk cabinet to it. When I boot from the VSI DVD, the disks mount and I can copy to/from them (this is just staging; they cannot stay on the system). When I boot the freshly installed VMS loaded from that DVD, none of the disks in that cabinet will mount; they are visible to VMS but are declared offline requiring operator intervention. I'll get patches and updates installed and do a little more testing.

Re: 'Partitioning' raid controller for VMS on Integrity

<1dca5d48-260d-44b8-ac42-86bc6b0d03a3n@googlegroups.com>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16924&group=comp.os.vms#16924

  copy link   Newsgroups: comp.os.vms
X-Received: by 2002:a05:620a:13cc:: with SMTP id g12mr3747844qkl.277.1631609364580;
Tue, 14 Sep 2021 01:49:24 -0700 (PDT)
X-Received: by 2002:a05:622a:148c:: with SMTP id t12mr3559217qtx.156.1631609364225;
Tue, 14 Sep 2021 01:49:24 -0700 (PDT)
Path: i2pn2.org!i2pn.org!weretis.net!feeder6.news.weretis.net!news.misty.com!border2.nntp.dca1.giganews.com!nntp.giganews.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: comp.os.vms
Date: Tue, 14 Sep 2021 01:49:24 -0700 (PDT)
In-Reply-To: <fe9d5d8e-fdf7-4a2b-9ab2-fad957d240efn@googlegroups.com>
Injection-Info: google-groups.googlegroups.com; posting-host=147.161.166.80; posting-account=378ChwoAAABjoKItx20WP37stEUsbGCj
NNTP-Posting-Host: 147.161.166.80
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
<shdok8$i1h$1@dont-email.me> <15c70f35-155d-45d7-8bb9-933b8a042507n@googlegroups.com>
<shecbh$6th$1@dont-email.me> <28d7ee6c-9789-4471-af7c-d089c57dc4d8n@googlegroups.com>
<3613a2ce-b9e5-454e-a916-1143ec4706ean@googlegroups.com> <fe9d5d8e-fdf7-4a2b-9ab2-fad957d240efn@googlegroups.com>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <1dca5d48-260d-44b8-ac42-86bc6b0d03a3n@googlegroups.com>
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
From: duncanjm...@btinternet.com (DuncanMorris)
Injection-Date: Tue, 14 Sep 2021 08:49:24 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
Lines: 144
 by: DuncanMorris - Tue, 14 Sep 2021 08:49 UTC

On Tuesday, 14 September 2021 at 00:07:32 UTC+1, Rich Jordan wrote:
> On Friday, September 10, 2021 at 9:26:35 AM UTC-5, Rich Jordan wrote:
> > On Friday, September 10, 2021 at 5:48:53 AM UTC-5, abrsvc wrote:
> > > On Thursday, September 9, 2021 at 9:28:21 PM UTC-4, Dave Froble wrote:
> > > > On 9/9/2021 7:48 PM, Rich Jordan wrote:
> > > >
> > > > > Thanks to all who responded. The older system has 18 drives providing nine mirrored volumes, plus another 6 mirrored 'universal' drives proving backup staging space. They are hoping that we can put in an RX-2800 with eight larger SAS drives (which even RAID'ed will add up to much more space) but due to the age and complexity of the software involved we really want to keep the same number of spindles/volumes visible to VMS. If possible without a second controller and more drives in a shelf. If we have to merge more than one or two disks together it will seriously increase the complexity of acceptance testing; everything should be clearly controlled via logicals but a lot of hands wrote a lot of software over 30+ years, so dropping to four large mirrorsets is not going to happen. I know we can do the work, but the time and cost...
> > > > >
> > > > > We have an RX2660 we use for testing here; it has a P410i with the advanced license and some 1.2TB SAS drives (and four smaller ones). I can make an ADG array with the four large drives in ORCA, but it does not provide any means of 'breaking that down' into smaller volumes to pass to VMS. I tried (once, so maybe missed something) to use MSA$UTIL from the DVD boot of HP VMS V8.4, and it also doesn't seem to have options to break down that large disk (which is already visible to VMS). So if a P410 can do this (is a P410i different in that regard?) I should be able to test on the 2660 and confirm that it can be done on the potential RX-2800.
> > > > >
> > > > > I'm installing VMS kit on a local disk temporarily so I can see if the MSA$UTIL options are different when booting from a live disk. I've got the appropriate update kits available to install
> > > > >
> > > > > If SAUPDATE from the UEFI console is also capable of doing the volume setups then I'm going to try to find that kit/download somewhere; HPe moved it all behind paywalls. I should have RX2620 firmware kits from when ours was under support but I doubt I have that for the 2660 (which was a customer letting us have it back when they retired); no idea if we could use one kit for just that one utility on a different box.
> > > > >
> > > > > Thanks again
> > > > >
> > > > I don't know how your system(s) are configured, so this may not be helpful.
> > > >
> > > > We use those "dratted logicals" to define disks. So we can move things
> > > > around, just with the logicals.
> > > >
> > > > Say:
> > > >
> > > > Disk0
> > > > Disk1
> > > > Disk2
> > > > Disk3
> > > >
> > > > Are current. However if we wanted to replace both Disk2 and Disk3 with
> > > > one larger disk, all we would do is to have both logical names Disk2 and
> > > > Disk3 both point to the new larger disk.
> > > >
> > > > There could still be issues. Say the old disks have identical directory
> > > > names that are used for different purposes. Or other unknown to me issues.
> > > >
> > > > If you're not using logical names in a like manner, then perhaps your
> > > > solutions will be a bit more difficult.
> > > > --
> > > > David Froble Tel: 724-529-0450
> > > > Dave Froble Enterprises, Inc. E-Mail: da...@tsoft-inc.com
> > > > DFE Ultralights, Inc.
> > > > 170 Grimplin Road
> > > > Vanderbilt, PA 15486
> > > The use of concealed devices can "fix" this too. I have successfully used these to accomplish having multiple "disks" on a single one.
> > >
> > > Dan
> > The system was designed with logicals. The devs over the years were supposed to use said logicals, and the last major system change 10 or so years go rooted out the mistakes when the Integrity disks had different names (for which we also used concealed logicals). However we want to avoid going through the effort needed to merge multiple current disks together onto fewer larger ones. Yes, there are overlaps in the directory structures between the drives. Old stuff, moved stuff, archived stuff, and the devs are not at all or barely available for questions.
> >
> > This is not an issue about overall disk size (other than getting more space, easy since the largest current spindle is 300GB mirrorset). If we 1.5x the size of every current disk (way more than enough given past growth) the seven data drives will still fit the 2.4TB 4 drive ADG that I set up on the test box.
> >
> > But we really want at least 7 spindles (8 or 9 better) with RAID protection without doing an external shelf and a whole other set of disks. Paritioning at the controller level would do that.
> >
> > We'll find out if msa$util from installed VMS (as opposed to DVD boot) can do something with the P410i in that regard. I can wipe and rebuild the ADG array for any testing.
> >
> > Rich
> And the results are in unless there's super secret MSA$UTIL commands that I don't have docs for. No go. The P410i apparently does not provide any means of generating individual disks that are a subset of a single RAID logical disk. Whether its a single disk or a mirror pair, or a RAID set with multiple disks, only the single unit is provided to VMS.
>
> We're going to look at the second controller and drive shelf to get 8 spindles; that will be enough to get by without major work. Hate losing the optical drive for that but that can be worked around.
>
> Interestingly... the 2660 has a SCSI Card in it for use with a tape library; it is the same card that I understand was spec'd for the RX-2800s. I hooked an external disk cabinet to it. When I boot from the VSI DVD, the disks mount and I can copy to/from them (this is just staging; they cannot stay on the system). When I boot the freshly installed VMS loaded from that DVD, none of the disks in that cabinet will mount; they are visible to VMS but are declared offline requiring operator intervention. I'll get patches and updates installed and do a little more testing.

The p40i has no problem presenting multiple units with MSA$UTIL to OpenVMS.
This example is from a recent colleague's update agenda for a client:

MSA> add unit 2/disk=(3,4,5,6,7,8)/raid=1/part=0/size=32GB ! Backup of Live system disk
MSA> add unit 3/disk=(3,4,5,6,7,8)/raid=1/part=1/size=8GB ! Copy of VSI VMS v8.4-2L3
MSA> add unit 4/disk=(3,4,5,6,7,8)/raid=1/part=2/size=20GB ! USER
MSA> add unit 5/disk=(3,4,5,6,7,8)/raid=1/part=3/size=10GB ! BATS
MSA> add unit 6/disk=(3,4,5,6,7,8)/raid=1/part=4/size=25GB ! DOCS
MSA> add unit 7/disk=(3,4,5,6,7,8)/raid=1/part=5/size=40GB ! DATA_1
MSA> add unit 8/disk=(3,4,5,6,7,8)/raid=1/part=6/size=40GB ! DATA_2
MSA> add unit 9/disk=(3,4,5,6,7,8)/raid=1/part=7/size=40GB ! INET_1
MSA> add unit 10/disk=(3,4,5,6,7,8)/raid=1/part=8/size=20GB ! INET_LOGS
MSA> add unit 11/disk=(3,4,5,6,7,8)/raid=1/part=9/size=150GB ! BACKUP

Re: 'Partitioning' raid controller for VMS on Integrity

<f3c1776d-15ba-4bb5-ab79-9aef59ff354en@googlegroups.com>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16943&group=comp.os.vms#16943

  copy link   Newsgroups: comp.os.vms
X-Received: by 2002:ae9:f304:: with SMTP id p4mr6397113qkg.334.1631642647695;
Tue, 14 Sep 2021 11:04:07 -0700 (PDT)
X-Received: by 2002:a05:622a:148c:: with SMTP id t12mr6052798qtx.156.1631642647531;
Tue, 14 Sep 2021 11:04:07 -0700 (PDT)
Path: i2pn2.org!i2pn.org!weretis.net!feeder6.news.weretis.net!news.misty.com!border2.nntp.dca1.giganews.com!nntp.giganews.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: comp.os.vms
Date: Tue, 14 Sep 2021 11:04:07 -0700 (PDT)
In-Reply-To: <1dca5d48-260d-44b8-ac42-86bc6b0d03a3n@googlegroups.com>
Injection-Info: google-groups.googlegroups.com; posting-host=162.251.133.98; posting-account=-m1l1AkAAAAOcQipwxcZ5ncqqoxN3l1E
NNTP-Posting-Host: 162.251.133.98
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
<shdok8$i1h$1@dont-email.me> <15c70f35-155d-45d7-8bb9-933b8a042507n@googlegroups.com>
<shecbh$6th$1@dont-email.me> <28d7ee6c-9789-4471-af7c-d089c57dc4d8n@googlegroups.com>
<3613a2ce-b9e5-454e-a916-1143ec4706ean@googlegroups.com> <fe9d5d8e-fdf7-4a2b-9ab2-fad957d240efn@googlegroups.com>
<1dca5d48-260d-44b8-ac42-86bc6b0d03a3n@googlegroups.com>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <f3c1776d-15ba-4bb5-ab79-9aef59ff354en@googlegroups.com>
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
From: jor...@ccs4vms.com (Rich Jordan)
Injection-Date: Tue, 14 Sep 2021 18:04:07 +0000
Content-Type: text/plain; charset="UTF-8"
Lines: 18
 by: Rich Jordan - Tue, 14 Sep 2021 18:04 UTC

On Tuesday, September 14, 2021 at 3:49:25 AM UTC-5, DuncanMorris wrote:

> The p40i has no problem presenting multiple units with MSA$UTIL to OpenVMS.
> This example is from a recent colleague's update agenda for a client:
>
> MSA> add unit 2/disk=(3,4,5,6,7,8)/raid=1/part=0/size=32GB ! Backup of Live system disk
> MSA> add unit 3/disk=(3,4,5,6,7,8)/raid=1/part=1/size=8GB ! Copy of VSI VMS v8.4-2L3
> MSA> add unit 4/disk=(3,4,5,6,7,8)/raid=1/part=2/size=20GB ! USER
> MSA> add unit 5/disk=(3,4,5,6,7,8)/raid=1/part=3/size=10GB ! BATS
> MSA> add unit 6/disk=(3,4,5,6,7,8)/raid=1/part=4/size=25GB ! DOCS
> MSA> add unit 7/disk=(3,4,5,6,7,8)/raid=1/part=5/size=40GB ! DATA_1
> MSA> add unit 8/disk=(3,4,5,6,7,8)/raid=1/part=6/size=40GB ! DATA_2
> MSA> add unit 9/disk=(3,4,5,6,7,8)/raid=1/part=7/size=40GB ! INET_1
> MSA> add unit 10/disk=(3,4,5,6,7,8)/raid=1/part=8/size=20GB ! INET_LOGS
> MSA> add unit 11/disk=(3,4,5,6,7,8)/raid=1/part=9/size=150GB ! BACKUP

Thank you! Will try that out on the 2660 and see what happens. I didn't dig deeply enough into the add command help.

Rich

Re: 'Partitioning' raid controller for VMS on Integrity

<shr599$20r$1@gioia.aioe.org>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=16963&group=comp.os.vms#16963

  copy link   Newsgroups: comp.os.vms
Path: i2pn2.org!i2pn.org!aioe.org!jazQyxryRFiI4FEZ51SAvA.user.46.165.242.75.POSTED!not-for-mail
From: chris-no...@tridac.net (chris)
Newsgroups: comp.os.vms
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
Date: Tue, 14 Sep 2021 22:47:21 +0100
Organization: Aioe.org NNTP Server
Message-ID: <shr599$20r$1@gioia.aioe.org>
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
Mime-Version: 1.0
Content-Type: text/plain; charset=UTF-8; format=flowed
Content-Transfer-Encoding: 7bit
Injection-Info: gioia.aioe.org; logging-data="2075"; posting-host="jazQyxryRFiI4FEZ51SAvA.user.gioia.aioe.org"; mail-complaints-to="abuse@aioe.org";
User-Agent: Mozilla/5.0 (X11; SunOS sun4u; rv:10.0.2) Gecko/20120216 Thunderbird/10.0.2
X-Notice: Filtered by postfilter v. 0.9.2
 by: chris - Tue, 14 Sep 2021 21:47 UTC

On 09/09/21 01:06, Rich Jordan wrote:
> VMS doesn't do partitions. Are there any SAS type RAID controllers for RX servers that can present 'partitioned' logical drives to VMS so it sees separate spindles?
>
> Wondering if it is possible at all to f/ex build a 4 disk ADG array and present more than one spindle to VMS from it.
>
> Thanks

Different approach? Proliant hp smart array controllers can
take a set of disks and present several logical drives, usually
mirror or raid 5 n, but down to single drive level, which might
be a solution.

Afaik, no ability to provide the unix style multiple hardware
partitions across s single drive. VMSmay have logical
drive subsetting capability via a single drive. RT11 V 5
certainly had and a driver to handle it...

Chris

Re: 'Partitioning' raid controller for VMS on Integrity

<d6588b36-467d-4525-bc2e-17edbe214197n@googlegroups.com>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=17046&group=comp.os.vms#17046

  copy link   Newsgroups: comp.os.vms
X-Received: by 2002:a37:9b16:: with SMTP id d22mr17484214qke.22.1632174559639;
Mon, 20 Sep 2021 14:49:19 -0700 (PDT)
X-Received: by 2002:ad4:4a21:: with SMTP id n1mr27537923qvz.22.1632174559433;
Mon, 20 Sep 2021 14:49:19 -0700 (PDT)
Path: i2pn2.org!i2pn.org!weretis.net!feeder6.news.weretis.net!news.misty.com!border2.nntp.dca1.giganews.com!nntp.giganews.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: comp.os.vms
Date: Mon, 20 Sep 2021 14:49:19 -0700 (PDT)
In-Reply-To: <f3c1776d-15ba-4bb5-ab79-9aef59ff354en@googlegroups.com>
Injection-Info: google-groups.googlegroups.com; posting-host=162.251.133.98; posting-account=-m1l1AkAAAAOcQipwxcZ5ncqqoxN3l1E
NNTP-Posting-Host: 162.251.133.98
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
<shdok8$i1h$1@dont-email.me> <15c70f35-155d-45d7-8bb9-933b8a042507n@googlegroups.com>
<shecbh$6th$1@dont-email.me> <28d7ee6c-9789-4471-af7c-d089c57dc4d8n@googlegroups.com>
<3613a2ce-b9e5-454e-a916-1143ec4706ean@googlegroups.com> <fe9d5d8e-fdf7-4a2b-9ab2-fad957d240efn@googlegroups.com>
<1dca5d48-260d-44b8-ac42-86bc6b0d03a3n@googlegroups.com> <f3c1776d-15ba-4bb5-ab79-9aef59ff354en@googlegroups.com>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <d6588b36-467d-4525-bc2e-17edbe214197n@googlegroups.com>
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
From: jor...@ccs4vms.com (Rich Jordan)
Injection-Date: Mon, 20 Sep 2021 21:49:19 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
Lines: 51
 by: Rich Jordan - Mon, 20 Sep 2021 21:49 UTC

On Tuesday, September 14, 2021 at 1:04:09 PM UTC-5, Rich Jordan wrote:
> On Tuesday, September 14, 2021 at 3:49:25 AM UTC-5, DuncanMorris wrote:
>
> > The p40i has no problem presenting multiple units with MSA$UTIL to OpenVMS.
> > This example is from a recent colleague's update agenda for a client:
> >
> > MSA> add unit 2/disk=(3,4,5,6,7,8)/raid=1/part=0/size=32GB ! Backup of Live system disk
> > MSA> add unit 3/disk=(3,4,5,6,7,8)/raid=1/part=1/size=8GB ! Copy of VSI VMS v8.4-2L3
> > MSA> add unit 4/disk=(3,4,5,6,7,8)/raid=1/part=2/size=20GB ! USER
> > MSA> add unit 5/disk=(3,4,5,6,7,8)/raid=1/part=3/size=10GB ! BATS
> > MSA> add unit 6/disk=(3,4,5,6,7,8)/raid=1/part=4/size=25GB ! DOCS
> > MSA> add unit 7/disk=(3,4,5,6,7,8)/raid=1/part=5/size=40GB ! DATA_1
> > MSA> add unit 8/disk=(3,4,5,6,7,8)/raid=1/part=6/size=40GB ! DATA_2
> > MSA> add unit 9/disk=(3,4,5,6,7,8)/raid=1/part=7/size=40GB ! INET_1
> > MSA> add unit 10/disk=(3,4,5,6,7,8)/raid=1/part=8/size=20GB ! INET_LOGS
> > MSA> add unit 11/disk=(3,4,5,6,7,8)/raid=1/part=9/size=150GB ! BACKUP
> Thank you! Will try that out on the 2660 and see what happens. I didn't dig deeply enough into the add command help.
>
> Rich

Duncan's info worked and now that I know the syntax I was able to find some references online; before that google-fu failed.

Is there a way to change the device name presented/selected by VMS on an Integrity server? I could swear I read somewhere that you could change the third letter by some kind of handwavium, I think in one of the EFI files or UEFI device management. So controller PKA0 (by default the dedicated slot P400i which comes up as PKA0) could be known to VMS as PKD0 (and its disks become DKD#)? Can't just move things around in slots to change the order, and so the naming.

Pretty sure there's no way to change individual disk names to reflect different controllers when they're all on the same one, but if we can change the seven data disks to DKD on this controller, we can work around the system, alt system, and staging disks also now being DKD# instead of DKC and DKA respectively. Logicals are good enough for those. I'd like to avoid using new logicals for anything related to the production drives though.

Re: 'Partitioning' raid controller for VMS on Integrity

<1ef3d9a0-c9e7-4b8a-a315-cd3b091e798cn@googlegroups.com>

  copy mid

https://www.novabbs.com/computers/article-flat.php?id=17637&group=comp.os.vms#17637

  copy link   Newsgroups: comp.os.vms
X-Received: by 2002:a05:622a:283:: with SMTP id z3mr8776385qtw.324.1633656398480;
Thu, 07 Oct 2021 18:26:38 -0700 (PDT)
X-Received: by 2002:ac8:11e:: with SMTP id e30mr2762939qtg.281.1633656398361;
Thu, 07 Oct 2021 18:26:38 -0700 (PDT)
Path: rocksolid2!i2pn.org!weretis.net!feeder6.news.weretis.net!news.misty.com!border2.nntp.dca1.giganews.com!nntp.giganews.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: comp.os.vms
Date: Thu, 7 Oct 2021 18:26:38 -0700 (PDT)
In-Reply-To: <d6588b36-467d-4525-bc2e-17edbe214197n@googlegroups.com>
Injection-Info: google-groups.googlegroups.com; posting-host=118.93.180.215; posting-account=Rx7iEQoAAACMdczcZGHsDFakQWn8-8-t
NNTP-Posting-Host: 118.93.180.215
References: <847b6f54-78a6-474a-baaf-391d50aa4dccn@googlegroups.com>
<shdok8$i1h$1@dont-email.me> <15c70f35-155d-45d7-8bb9-933b8a042507n@googlegroups.com>
<shecbh$6th$1@dont-email.me> <28d7ee6c-9789-4471-af7c-d089c57dc4d8n@googlegroups.com>
<3613a2ce-b9e5-454e-a916-1143ec4706ean@googlegroups.com> <fe9d5d8e-fdf7-4a2b-9ab2-fad957d240efn@googlegroups.com>
<1dca5d48-260d-44b8-ac42-86bc6b0d03a3n@googlegroups.com> <f3c1776d-15ba-4bb5-ab79-9aef59ff354en@googlegroups.com>
<d6588b36-467d-4525-bc2e-17edbe214197n@googlegroups.com>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <1ef3d9a0-c9e7-4b8a-a315-cd3b091e798cn@googlegroups.com>
Subject: Re: 'Partitioning' raid controller for VMS on Integrity
From: lawrence...@gmail.com (Lawrence D’Oliveiro)
Injection-Date: Fri, 08 Oct 2021 01:26:38 +0000
Content-Type: text/plain; charset="UTF-8"
Lines: 8
 by: Lawrence D’Oliveir - Fri, 8 Oct 2021 01:26 UTC

On Tuesday, September 21, 2021 at 9:49:20 AM UTC+12, Rich Jordan wrote:
> Is there a way to change the device name presented/selected by VMS on an Integrity server?
> I could swear I read somewhere that you could change the third letter by some kind of
> handwavium, I think in one of the EFI files or UEFI device management. So controller PKA0
> (by default the dedicated slot P400i which comes up as PKA0) could be known to VMS as
> PKD0 (and its disks become DKD#)? Can't just move things around in slots to change the
> order, and so the naming.

But ... but ... 26 drive letters ought to be enough for anybody!