flat plate convection cooling calcs

<l231ch96l467r9ra0dgondgacad99pq90m@4ax.com>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=100728&group=sci.electronics.design#100728

  copy link   Newsgroups: sci.electronics.design
Path: i2pn2.org!i2pn.org!weretis.net!feeder8.news.weretis.net!3.eu.feeder.erje.net!feeder.erje.net!border1.nntp.dca1.giganews.com!nntp.giganews.com!buffer1.nntp.dca1.giganews.com!nntp.supernews.com!news.supernews.com.POSTED!not-for-mail
NNTP-Posting-Date: Sat, 02 Jul 2022 13:40:12 -0500
From: jlar...@highlandsniptechnology.com
Newsgroups: sci.electronics.design
Subject: flat plate convection cooling calcs
Date: Sat, 02 Jul 2022 11:40:04 -0700
Message-ID: <l231ch96l467r9ra0dgondgacad99pq90m@4ax.com>
X-Newsreader: Forte Agent 3.1/32.783
MIME-Version: 1.0
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit
Lines: 8
X-Trace: sv3-hgh8WpcoiJIqTpEqhme8rc4QVfIsPLqNAGj65S20TBvg2YhSPkqFGnLvB0ctkhFXo/q18PPR4h1ZZgy!JPza9anxp5lGeMGOqq7twQj2nsod4g9gZrTZqFRLSokDT5YyV4cdhmv449pEEx7VMamr6TcosrdX!SbFtlQ==
X-Complaints-To: www.supernews.com/docs/abuse.html
X-DMCA-Complaints-To: www.supernews.com/docs/dmca.html
X-Abuse-and-DMCA-Info: Please be sure to forward a copy of ALL headers
X-Abuse-and-DMCA-Info: Otherwise we will be unable to process your complaint properly
X-Postfilter: 1.3.40
X-Original-Bytes: 1271
 by: jlar...@highlandsniptechnology.com - Sat, 2 Jul 2022 18:40 UTC

https://thermal.mayahtt.com/tmwiz/convect/forced/fp-isot/fp-isot.htm

is a calculator for forced-air heat transfer of a flat plate.

https://www.efunda.com/formulae/heat_transfer/convection_forced/calc_lamflow_isothermalplate.cfm#calc

another one. The results seem pretty close.

Re: flat plate convection cooling calcs

<t9qbmv$1qsk$1@gioia.aioe.org>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=100730&group=sci.electronics.design#100730

  copy link   Newsgroups: sci.electronics.design
Path: i2pn2.org!i2pn.org!aioe.org!xUOiStaTX9GQDNXPji0+sg.user.46.165.242.75.POSTED!not-for-mail
From: bl...@ckb.ird (corvid)
Newsgroups: sci.electronics.design
Subject: Re: flat plate convection cooling calcs
Date: Sat, 2 Jul 2022 14:01:18 -0700
Organization: The 27 Club
Message-ID: <t9qbmv$1qsk$1@gioia.aioe.org>
References: <l231ch96l467r9ra0dgondgacad99pq90m@4ax.com>
Mime-Version: 1.0
Content-Type: text/plain; charset=UTF-8; format=flowed
Content-Transfer-Encoding: 7bit
Injection-Info: gioia.aioe.org; logging-data="60308"; posting-host="xUOiStaTX9GQDNXPji0+sg.user.gioia.aioe.org"; mail-complaints-to="abuse@aioe.org";
User-Agent: Mozilla/5.0 (Macintosh; Intel Mac OS X 10.15; rv:91.0)
Gecko/20100101 Thunderbird/91.11.0
Content-Language: en-US
X-Notice: Filtered by postfilter v. 0.9.2
 by: corvid - Sat, 2 Jul 2022 21:01 UTC

On 7/2/22 11:40, jlarkin@highlandsniptechnology.com wrote:
> https://thermal.mayahtt.com/tmwiz/convect/forced/fp-isot/fp-isot.htm
>
> is a calculator for forced-air heat transfer of a flat plate.
>
> https://www.efunda.com/formulae/heat_transfer/convection_forced/calc_lamflow_isothermalplate.cfm#calc
>
> another one. The results seem pretty close.

Does it work backward, when the air is hotter than the plate?

Re: flat plate convection cooling calcs

<t9qclh$51g$1@gioia.aioe.org>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=100731&group=sci.electronics.design#100731

  copy link   Newsgroups: sci.electronics.design
Path: i2pn2.org!i2pn.org!aioe.org!xUOiStaTX9GQDNXPji0+sg.user.46.165.242.75.POSTED!not-for-mail
From: bl...@ckb.ird (corvid)
Newsgroups: sci.electronics.design
Subject: Re: flat plate convection cooling calcs
Date: Sat, 2 Jul 2022 14:17:37 -0700
Organization: The 27 Club
Message-ID: <t9qclh$51g$1@gioia.aioe.org>
References: <l231ch96l467r9ra0dgondgacad99pq90m@4ax.com>
<t9qbmv$1qsk$1@gioia.aioe.org>
Mime-Version: 1.0
Content-Type: text/plain; charset=UTF-8; format=flowed
Content-Transfer-Encoding: 8bit
Injection-Info: gioia.aioe.org; logging-data="5168"; posting-host="xUOiStaTX9GQDNXPji0+sg.user.gioia.aioe.org"; mail-complaints-to="abuse@aioe.org";
User-Agent: Mozilla/5.0 (Macintosh; Intel Mac OS X 10.15; rv:91.0)
Gecko/20100101 Thunderbird/91.11.0
Content-Language: en-US
X-Notice: Filtered by postfilter v. 0.9.2
 by: corvid - Sat, 2 Jul 2022 21:17 UTC

On 7/2/22 14:01, corvid wrote:
> On 7/2/22 11:40, jlarkin@highlandsniptechnology.com wrote:
>> https://thermal.mayahtt.com/tmwiz/convect/forced/fp-isot/fp-isot.htm
>>
>> is a calculator for forced-air heat transfer of a flat plate.
>>
>> https://www.efunda.com/formulae/heat_transfer/convection_forced/calc_lamflow_isothermalplate.cfm#calc
>>
>>
>>  another one. The results seem pretty close.
>
> Does it work backward, when the air is hotter than the plate?

Stupid question is coming up, that wasn't it.

Re: flat plate convection cooling calcs

<s2e1ch9ro6bi4uv2209p7kp2jnbcjmjj6b@4ax.com>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=100732&group=sci.electronics.design#100732

  copy link   Newsgroups: sci.electronics.design
Path: i2pn2.org!i2pn.org!weretis.net!feeder6.news.weretis.net!1.us.feeder.erje.net!feeder.erje.net!border1.nntp.dca1.giganews.com!nntp.giganews.com!buffer1.nntp.dca1.giganews.com!nntp.supernews.com!news.supernews.com.POSTED!not-for-mail
NNTP-Posting-Date: Sat, 02 Jul 2022 16:28:41 -0500
From: jlar...@highlandsniptechnology.com
Newsgroups: sci.electronics.design
Subject: Re: flat plate convection cooling calcs
Date: Sat, 02 Jul 2022 14:28:33 -0700
Message-ID: <s2e1ch9ro6bi4uv2209p7kp2jnbcjmjj6b@4ax.com>
References: <l231ch96l467r9ra0dgondgacad99pq90m@4ax.com> <t9qbmv$1qsk$1@gioia.aioe.org>
X-Newsreader: Forte Agent 3.1/32.783
MIME-Version: 1.0
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit
Lines: 15
X-Trace: sv3-bqwpetnfaaD1ogRWMJN76JCRh/DTib+rpZGsTCYEkfdVUGzzDoQs1PJaRJUZ9LUEJSgdF6aQfokUuTq!7eMnhDcbYI2SnYakSnO+lmB2+QNgLRhdzR5EDUjGpSw+JU1UAJz4B5OCBlewV9Smq5kTyP2z/dos!SB5+/w==
X-Complaints-To: www.supernews.com/docs/abuse.html
X-DMCA-Complaints-To: www.supernews.com/docs/dmca.html
X-Abuse-and-DMCA-Info: Please be sure to forward a copy of ALL headers
X-Abuse-and-DMCA-Info: Otherwise we will be unable to process your complaint properly
X-Postfilter: 1.3.40
X-Original-Bytes: 1616
 by: jlar...@highlandsniptechnology.com - Sat, 2 Jul 2022 21:28 UTC

On Sat, 2 Jul 2022 14:01:18 -0700, corvid <bl@ckb.ird> wrote:

>On 7/2/22 11:40, jlarkin@highlandsniptechnology.com wrote:
>> https://thermal.mayahtt.com/tmwiz/convect/forced/fp-isot/fp-isot.htm
>>
>> is a calculator for forced-air heat transfer of a flat plate.
>>
>> https://www.efunda.com/formulae/heat_transfer/convection_forced/calc_lamflow_isothermalplate.cfm#calc
>>
>> another one. The results seem pretty close.
>
>Does it work backward, when the air is hotter than the plate?

Probably, excepting condensation.