* Data Centers, Backbone of the Digital Economy, Face Water ScarcityFred Bloggs
+* Re: Data Centers, Backbone of the Digital Economy, Face Waterwhit3rd
|`- Re: Data Centers, Backbone of the Digital Economy, Face WaterFred Bloggs
`* Re: Data Centers, Backbone of the Digital Economy, Face WaterFred Bloggs
 `- Re: Data Centers, Backbone of the Digital Economy, Face WaterFred Bloggs

1
Data Centers, Backbone of the Digital Economy, Face Water Scarcity and Climate Risk

<2d97a21a-0666-4425-be0c-3d343346e67en@googlegroups.com>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=105007&group=sci.electronics.design#105007

  copy link   Newsgroups: sci.electronics.design
X-Received: by 2002:a05:620a:4502:b0:6b4:6c2f:e7b7 with SMTP id t2-20020a05620a450200b006b46c2fe7b7mr18040494qkp.11.1661998341476;
Wed, 31 Aug 2022 19:12:21 -0700 (PDT)
X-Received: by 2002:a25:1641:0:b0:684:d31a:feff with SMTP id
62-20020a251641000000b00684d31afeffmr18267376ybw.538.1661998341145; Wed, 31
Aug 2022 19:12:21 -0700 (PDT)
Path: i2pn2.org!rocksolid2!i2pn.org!usenet.blueworldhosting.com!feed1.usenet.blueworldhosting.com!peer02.iad!feed-me.highwinds-media.com!news.highwinds-media.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: sci.electronics.design
Date: Wed, 31 Aug 2022 19:12:20 -0700 (PDT)
Injection-Info: google-groups.googlegroups.com; posting-host=2601:5cc:4701:5250:7566:5ea8:f8ab:ea2b;
posting-account=iGtwSwoAAABNNwPORfvAs6OM4AR9GRHt
NNTP-Posting-Host: 2601:5cc:4701:5250:7566:5ea8:f8ab:ea2b
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <2d97a21a-0666-4425-be0c-3d343346e67en@googlegroups.com>
Subject: Data Centers, Backbone of the Digital Economy, Face Water Scarcity
and Climate Risk
From: bloggs.f...@gmail.com (Fred Bloggs)
Injection-Date: Thu, 01 Sep 2022 02:12:21 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
X-Received-Bytes: 1767
 by: Fred Bloggs - Thu, 1 Sep 2022 02:12 UTC

"All told, a mid-sized data center consumes around 300,000 gallons of water a day, or about as much as 1,000 U.S. households, says Shehabi of Lawrence Berkeley National Laboratory. Their direct, on-site consumption ranks data centers among the top 10 water users in America's industrial and commercial sectors."

This is not looking good at all:

https://www.kqed.org/science/1980170/data-centers-backbone-of-the-digital-economy-face-water-scarcity-and-climate-risk

Hard to believe they committed to these stupid designs in places with a pretty well-established record of water shortages.

Re: Data Centers, Backbone of the Digital Economy, Face Water Scarcity and Climate Risk

<942b4a31-5d22-4009-bf42-c902ec08223dn@googlegroups.com>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=105017&group=sci.electronics.design#105017

  copy link   Newsgroups: sci.electronics.design
X-Received: by 2002:a05:622a:1895:b0:344:f8dc:d070 with SMTP id v21-20020a05622a189500b00344f8dcd070mr21907344qtc.416.1662003243602;
Wed, 31 Aug 2022 20:34:03 -0700 (PDT)
X-Received: by 2002:a25:becd:0:b0:690:a05c:8103 with SMTP id
k13-20020a25becd000000b00690a05c8103mr17046333ybm.381.1662003243253; Wed, 31
Aug 2022 20:34:03 -0700 (PDT)
Path: i2pn2.org!i2pn.org!usenet.blueworldhosting.com!feed1.usenet.blueworldhosting.com!peer02.iad!feed-me.highwinds-media.com!news.highwinds-media.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: sci.electronics.design
Date: Wed, 31 Aug 2022 20:34:03 -0700 (PDT)
In-Reply-To: <2d97a21a-0666-4425-be0c-3d343346e67en@googlegroups.com>
Injection-Info: google-groups.googlegroups.com; posting-host=209.221.140.126; posting-account=vKQm_QoAAADOaDCYsqOFDAW8NJ8sFHoE
NNTP-Posting-Host: 209.221.140.126
References: <2d97a21a-0666-4425-be0c-3d343346e67en@googlegroups.com>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <942b4a31-5d22-4009-bf42-c902ec08223dn@googlegroups.com>
Subject: Re: Data Centers, Backbone of the Digital Economy, Face Water
Scarcity and Climate Risk
From: whit...@gmail.com (whit3rd)
Injection-Date: Thu, 01 Sep 2022 03:34:03 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
X-Received-Bytes: 2183
 by: whit3rd - Thu, 1 Sep 2022 03:34 UTC

On Wednesday, August 31, 2022 at 7:12:25 PM UTC-7, Fred Bloggs wrote:
> "All told, a mid-sized data center consumes around 300,000 gallons of water a day, or about as much as 1,000 U.S. households, says Shehabi of Lawrence Berkeley National Laboratory. Their direct, on-site consumption ranks data centers among the top 10 water users in America's industrial and commercial sectors."
>
> This is not looking good at all:
>
> https://www.kqed.org/science/1980170/data-centers-backbone-of-the-digital-economy-face-water-scarcity-and-climate-risk
>
> Hard to believe they committed to these stupid designs in places with a pretty well-established record of water shortages.

Maybe that's why Microsoft is sinking some in the plentiful (most of Earth's surface) salt
waters.

<https://www.theverge.com/2020/9/14/21436746/microsoft-project-natick-data-center-server-underwater-cooling-reliability>

Re: Data Centers, Backbone of the Digital Economy, Face Water Scarcity and Climate Risk

<9bd58083-40b4-4ae3-b430-cb95c9c6f45cn@googlegroups.com>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=105049&group=sci.electronics.design#105049

  copy link   Newsgroups: sci.electronics.design
X-Received: by 2002:ae9:e70f:0:b0:6bb:eb30:4916 with SMTP id m15-20020ae9e70f000000b006bbeb304916mr19600391qka.691.1662037333940;
Thu, 01 Sep 2022 06:02:13 -0700 (PDT)
X-Received: by 2002:a81:5257:0:b0:344:c847:90c1 with SMTP id
g84-20020a815257000000b00344c84790c1mr30576ywb.180.1662037333636; Thu, 01 Sep
2022 06:02:13 -0700 (PDT)
Path: i2pn2.org!i2pn.org!usenet.blueworldhosting.com!feed1.usenet.blueworldhosting.com!peer02.iad!feed-me.highwinds-media.com!news.highwinds-media.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: sci.electronics.design
Date: Thu, 1 Sep 2022 06:02:13 -0700 (PDT)
In-Reply-To: <942b4a31-5d22-4009-bf42-c902ec08223dn@googlegroups.com>
Injection-Info: google-groups.googlegroups.com; posting-host=2601:5cc:4701:5250:41e3:7e0e:79af:7eb1;
posting-account=iGtwSwoAAABNNwPORfvAs6OM4AR9GRHt
NNTP-Posting-Host: 2601:5cc:4701:5250:41e3:7e0e:79af:7eb1
References: <2d97a21a-0666-4425-be0c-3d343346e67en@googlegroups.com> <942b4a31-5d22-4009-bf42-c902ec08223dn@googlegroups.com>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <9bd58083-40b4-4ae3-b430-cb95c9c6f45cn@googlegroups.com>
Subject: Re: Data Centers, Backbone of the Digital Economy, Face Water
Scarcity and Climate Risk
From: bloggs.f...@gmail.com (Fred Bloggs)
Injection-Date: Thu, 01 Sep 2022 13:02:13 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
X-Received-Bytes: 2652
 by: Fred Bloggs - Thu, 1 Sep 2022 13:02 UTC

On Wednesday, August 31, 2022 at 11:34:07 PM UTC-4, whit3rd wrote:
> On Wednesday, August 31, 2022 at 7:12:25 PM UTC-7, Fred Bloggs wrote:
> > "All told, a mid-sized data center consumes around 300,000 gallons of water a day, or about as much as 1,000 U.S. households, says Shehabi of Lawrence Berkeley National Laboratory. Their direct, on-site consumption ranks data centers among the top 10 water users in America's industrial and commercial sectors."
> >
> > This is not looking good at all:
> >
> > https://www.kqed.org/science/1980170/data-centers-backbone-of-the-digital-economy-face-water-scarcity-and-climate-risk
> >
> > Hard to believe they committed to these stupid designs in places with a pretty well-established record of water shortages.
> Maybe that's why Microsoft is sinking some in the plentiful (most of Earth's surface) salt
> waters.
>
> <https://www.theverge.com/2020/9/14/21436746/microsoft-project-natick-data-center-server-underwater-cooling-reliability>

That makes a lot of sense. Without phase change, circulating water to absorb heat generally sucks at 1 BTU per pound per degree F. Since 1W is 3.4 BTUH, that translates into a humongous amount of water circulation for a typical data center.

Re: Data Centers, Backbone of the Digital Economy, Face Water Scarcity and Climate Risk

<10312efa-b82f-4113-b74b-e9933b0d6c5bn@googlegroups.com>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=105108&group=sci.electronics.design#105108

  copy link   Newsgroups: sci.electronics.design
X-Received: by 2002:a05:6214:d89:b0:479:6726:7f42 with SMTP id e9-20020a0562140d8900b0047967267f42mr26714091qve.20.1662083907895;
Thu, 01 Sep 2022 18:58:27 -0700 (PDT)
X-Received: by 2002:a0d:ca8f:0:b0:344:8998:21e4 with SMTP id
m137-20020a0dca8f000000b00344899821e4mr5203644ywd.347.1662083907590; Thu, 01
Sep 2022 18:58:27 -0700 (PDT)
Path: i2pn2.org!i2pn.org!usenet.blueworldhosting.com!feed1.usenet.blueworldhosting.com!peer01.iad!feed-me.highwinds-media.com!news.highwinds-media.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: sci.electronics.design
Date: Thu, 1 Sep 2022 18:58:27 -0700 (PDT)
In-Reply-To: <450264f3-5980-4070-bef2-228bb0ad817fn@googlegroups.com>
Injection-Info: google-groups.googlegroups.com; posting-host=2601:5cc:4701:5250:8c76:7a1a:e025:63b6;
posting-account=iGtwSwoAAABNNwPORfvAs6OM4AR9GRHt
NNTP-Posting-Host: 2601:5cc:4701:5250:8c76:7a1a:e025:63b6
References: <2d97a21a-0666-4425-be0c-3d343346e67en@googlegroups.com> <450264f3-5980-4070-bef2-228bb0ad817fn@googlegroups.com>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <10312efa-b82f-4113-b74b-e9933b0d6c5bn@googlegroups.com>
Subject: Re: Data Centers, Backbone of the Digital Economy, Face Water
Scarcity and Climate Risk
From: bloggs.f...@gmail.com (Fred Bloggs)
Injection-Date: Fri, 02 Sep 2022 01:58:27 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
X-Received-Bytes: 3262
 by: Fred Bloggs - Fri, 2 Sep 2022 01:58 UTC

On Thursday, September 1, 2022 at 8:30:37 PM UTC-4, bill....@ieee.org wrote:
> On Thursday, September 1, 2022 at 12:12:25 PM UTC+10, Fred Bloggs wrote:
> > "All told, a mid-sized data center consumes around 300,000 gallons of water a day, or about as much as 1,000 U.S. households, says Shehabi of Lawrence Berkeley National Laboratory. Their direct, on-site consumption ranks data centers among the top 10 water users in America's industrial and commercial sectors."
> >
> > This is not looking good at all:
> >
> > https://www.kqed.org/science/1980170/data-centers-backbone-of-the-digital-economy-face-water-scarcity-and-climate-risk
> >
> > Hard to believe they committed to these stupid designs in places with a pretty well-established record of water shortages.
> Seems nuts. Heat pipes evaporate water to shift heat, then condense it at the other end of the pipe to get rid of the heat.
>
> Put a compressor somewhere along that pipe and you can force the water vapour to condense at a much higher temperature than you used to evaporate it..
>
> It's a closed system, but it does use more electricity than you'd use if you simply let the water evaporate.

The chemistry of material compatibility and thermodynamic considerations really complicate things, but it's not anything that can't be handled:
https://www.boydcorp.com/resources/temperature-control/best-heat-transfer-fluids.html

Here's a simplified description of how cooling towers are used for the condensing heat removal phase of operation. Looks like they don't recirculate the water, it is a constant stream sprayed on the heat exchanger and from there down the drain. It's no wonder these idiots are using so much water!
https://waterchillers.com/blog/post/how-cooling-tower-vs-chillers-work

>
> --
> Bill Sloman, Sydney

Re: Data Centers, Backbone of the Digital Economy, Face Water Scarcity and Climate Risk

<30ab97ed-a5b0-4038-b949-ce3f83a533a1n@googlegroups.com>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=105118&group=sci.electronics.design#105118

  copy link   Newsgroups: sci.electronics.design
X-Received: by 2002:a05:622a:1986:b0:343:225d:f9e1 with SMTP id u6-20020a05622a198600b00343225df9e1mr28081071qtc.651.1662119317950;
Fri, 02 Sep 2022 04:48:37 -0700 (PDT)
X-Received: by 2002:a25:9109:0:b0:6a6:2aa8:955b with SMTP id
v9-20020a259109000000b006a62aa8955bmr320580ybl.381.1662119317692; Fri, 02 Sep
2022 04:48:37 -0700 (PDT)
Path: i2pn2.org!i2pn.org!usenet.blueworldhosting.com!feed1.usenet.blueworldhosting.com!peer01.iad!feed-me.highwinds-media.com!news.highwinds-media.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: sci.electronics.design
Date: Fri, 2 Sep 2022 04:48:37 -0700 (PDT)
In-Reply-To: <6b257722-c0f5-4c1b-8233-d9863ea35f8dn@googlegroups.com>
Injection-Info: google-groups.googlegroups.com; posting-host=2601:5cc:4701:5250:8542:7471:5479:60df;
posting-account=iGtwSwoAAABNNwPORfvAs6OM4AR9GRHt
NNTP-Posting-Host: 2601:5cc:4701:5250:8542:7471:5479:60df
References: <2d97a21a-0666-4425-be0c-3d343346e67en@googlegroups.com>
<450264f3-5980-4070-bef2-228bb0ad817fn@googlegroups.com> <10312efa-b82f-4113-b74b-e9933b0d6c5bn@googlegroups.com>
<6b257722-c0f5-4c1b-8233-d9863ea35f8dn@googlegroups.com>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <30ab97ed-a5b0-4038-b949-ce3f83a533a1n@googlegroups.com>
Subject: Re: Data Centers, Backbone of the Digital Economy, Face Water
Scarcity and Climate Risk
From: bloggs.f...@gmail.com (Fred Bloggs)
Injection-Date: Fri, 02 Sep 2022 11:48:37 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
X-Received-Bytes: 4473
 by: Fred Bloggs - Fri, 2 Sep 2022 11:48 UTC

On Friday, September 2, 2022 at 4:51:06 AM UTC-4, bill....@ieee.org wrote:
> On Friday, September 2, 2022 at 11:58:31 AM UTC+10, Fred Bloggs wrote:
> > On Thursday, September 1, 2022 at 8:30:37 PM UTC-4, bill....@ieee.org wrote:
> > > On Thursday, September 1, 2022 at 12:12:25 PM UTC+10, Fred Bloggs wrote:
> > > > "All told, a mid-sized data center consumes around 300,000 gallons of water a day, or about as much as 1,000 U.S. households, says Shehabi of Lawrence Berkeley National Laboratory. Their direct, on-site consumption ranks data centers among the top 10 water users in America's industrial and commercial sectors."
> > > >
> > > > This is not looking good at all:
> > > >
> > > > https://www.kqed.org/science/1980170/data-centers-backbone-of-the-digital-economy-face-water-scarcity-and-climate-risk
> > > >
> > > > Hard to believe they committed to these stupid designs in places with a pretty well-established record of water shortages.
> > > Seems nuts. Heat pipes evaporate water to shift heat, then condense it at the other end of the pipe to get rid of the heat.
> > >
> > > Put a compressor somewhere along that pipe and you can force the water vapour to condense at a much higher temperature than you used to evaporate it.
> > >
> > > It's a closed system, but it does use more electricity than you'd use if you simply let the water evaporate.
> >
> > The chemistry of material compatibility and thermodynamic considerations really complicate things, but it's not anything that can't be handled:
> > https://www.boydcorp.com/resources/temperature-control/best-heat-transfer-fluids.html
> This isn't any kind of complicated exposition - it's heat transfer fluids for dummies.

They're trying to summarize the highlights of all the various cooling liquids in 500 words or less.

>
> If you put water in a closed system it needs to be de-ionised. Adding a bit of glycol makes sense if can get cold and you don't want it to freeze.
> > Here's a simplified description of how cooling towers are used for the condensing heat removal phase of operation. Looks like they don't recirculate the water, it is a constant stream sprayed on the heat exchanger and from there down the drain. It's no wonder these idiots are using so much water!
> >
> > https://waterchillers.com/blog/post/how-cooling-tower-vs-chillers-work
> And need to scrape off the dissolved solids from time to time. It is pretty idiotic. Closed systems are better behaved, but they aren't dirt cheap,

That's just it. They want to keep the buy-in costs low, and play down the lifecycle costs of maintenance and replacement.

Those towers are where the legionella forms up too- so much so workers have to wear hazmat suits to get near it.

Hey- let's put the building fresh air exchange intake close by too.

>
> --
> Bill Sloman, Sydney

1