Rocksolid Light

Welcome to novaBBS (click a section below)

mail  files  register  newsreader  groups  login

Message-ID:  

Information is the inverse of entropy.


tech / sci.electronics.design / Re: Mains power voltage drop to reduce usage?

SubjectAuthor
o Re: Mains power voltage drop to reduce usage?whit3rd

1
Re: Mains power voltage drop to reduce usage?

<31c13ae9-66e6-4270-8954-1ec3342ad281n@googlegroups.com>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=110361&group=sci.electronics.design#110361

  copy link   Newsgroups: sci.electronics.design
X-Received: by 2002:a05:620a:a93:b0:6f9:de1b:8814 with SMTP id v19-20020a05620a0a9300b006f9de1b8814mr3977845qkg.18.1668729196049;
Thu, 17 Nov 2022 15:53:16 -0800 (PST)
X-Received: by 2002:ac8:5516:0:b0:3a5:1c8a:c0eb with SMTP id
j22-20020ac85516000000b003a51c8ac0ebmr4576211qtq.659.1668729195900; Thu, 17
Nov 2022 15:53:15 -0800 (PST)
Path: i2pn2.org!i2pn.org!usenet.blueworldhosting.com!feed1.usenet.blueworldhosting.com!peer01.iad!feed-me.highwinds-media.com!news.highwinds-media.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: sci.electronics.design
Date: Thu, 17 Nov 2022 15:53:15 -0800 (PST)
In-Reply-To: <u4ei4j-qbk.ln1@Telcontar.valinor>
Injection-Info: google-groups.googlegroups.com; posting-host=209.221.140.126; posting-account=vKQm_QoAAADOaDCYsqOFDAW8NJ8sFHoE
NNTP-Posting-Host: 209.221.140.126
References: <op.1u7t9bhtmvhs6z@ryzen.home> <tkm2aq$1tiv$1@gioia.aioe.org>
<op.1vivflqomvhs6z@ryzen.home> <k8k44j-3oq.ln1@Telcontar.valinor>
<op.1vixzaqhmvhs6z@ryzen.home> <gdf54j-vjm.ln1@Telcontar.valinor>
<tkqi1v$1e9l7$11@dont-email.me> <op.1vskjtwvmvhs6z@ryzen.home> <u4ei4j-qbk.ln1@Telcontar.valinor>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <31c13ae9-66e6-4270-8954-1ec3342ad281n@googlegroups.com>
Subject: Re: Mains power voltage drop to reduce usage?
From: whit...@gmail.com (whit3rd)
Injection-Date: Thu, 17 Nov 2022 23:53:16 +0000
Content-Type: text/plain; charset="UTF-8"
X-Received-Bytes: 2050
 by: whit3rd - Thu, 17 Nov 2022 23:53 UTC

On Thursday, November 17, 2022 at 11:24:14 AM UTC-8, Carlos E.R. wrote:
> On 2022-11-17 20:03, Commander Kinsey wrote:

> > I thought there was a problem with capacitance sending AC a long
> > distance, hence DC to the UK? Yet they're managing AC throughout
> > most of Europe?
> There is a problem with capacitance and inductance sending high voltage
> underground or undersea for significant distances, which DC doesn't have.

.... to which one should add, the problems of corona (which requires fat cables
in air) and earth conduction (a leakage resistance that inductively couples to AC)
which limit all installations, even airborne lines that don't take the low paths.