Rocksolid Light

Welcome to novaBBS (click a section below)

mail  files  register  newsreader  groups  login

Message-ID:  

GIVE: Support the helpless victims of computer error.


tech / sci.electronics.design / Electrostatic emulsion separation [Bill Sloman]

SubjectAuthor
* Electrostatic emulsion separation [Bill Sloman]Lamont Cranston
`* Re: Electrostatic emulsion separation [Bill Sloman]Phil Hobbs
 +- Re: Electrostatic emulsion separation [Bill Sloman]Lamont Cranston
 `* Re: Electrostatic emulsion separation [Bill Sloman]Lamont Cranston
  `* Re: Electrostatic emulsion separation [Bill Sloman]Lamont Cranston
   `* Re: Electrostatic emulsion separation [Bill Sloman]John S
    `- Re: Electrostatic emulsion separation [Bill Sloman]Lamont Cranston

1
Electrostatic emulsion separation [Bill Sloman]

<58510804-bed0-4c83-bc64-f82e050c54edn@googlegroups.com>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=127061&group=sci.electronics.design#127061

  copy link   Newsgroups: sci.electronics.design
X-Received: by 2002:a05:620a:4145:b0:767:fe53:3691 with SMTP id k5-20020a05620a414500b00767fe533691mr17109qko.3.1692229345335;
Wed, 16 Aug 2023 16:42:25 -0700 (PDT)
X-Received: by 2002:a05:6a00:1812:b0:687:94c5:6d99 with SMTP id
y18-20020a056a00181200b0068794c56d99mr1488216pfa.4.1692229344986; Wed, 16 Aug
2023 16:42:24 -0700 (PDT)
Path: i2pn2.org!i2pn.org!weretis.net!feeder6.news.weretis.net!newsfeed.hasname.com!usenet.blueworldhosting.com!diablo1.usenet.blueworldhosting.com!peer02.iad!feed-me.highwinds-media.com!news.highwinds-media.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: sci.electronics.design
Date: Wed, 16 Aug 2023 16:42:24 -0700 (PDT)
Injection-Info: google-groups.googlegroups.com; posting-host=69.1.57.19; posting-account=CCHfRQoAAABYiM-2uDHkSWkyFSzTOd-m
NNTP-Posting-Host: 69.1.57.19
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <58510804-bed0-4c83-bc64-f82e050c54edn@googlegroups.com>
Subject: Electrostatic emulsion separation [Bill Sloman]
From: amd...@gmail.com (Lamont Cranston)
Injection-Date: Wed, 16 Aug 2023 23:42:25 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
X-Received-Bytes: 1705
 by: Lamont Cranston - Wed, 16 Aug 2023 23:42 UTC

Anyone is free to answer, I just wanted Bill look at it.
Running tests on the 2"x2"x 34" glass vessel with aluminum tape electrodes on two sides. The emulsion is 23% water and 77% soybean oil.
The first test the water was clean, we drain the unit shake the oil to get a new emulsion and repeat the test with some small change and run again, every subsequent test we get nearly the same separation in the same time, but the water is now cloudy/darker. My son said he has noticed the phenomenon before.
Why would a first test have clean water and repeats
with the same solution have cloudy/darker water?
Thanks All.

Re: Electrostatic emulsion separation [Bill Sloman]

<ubjoad$3ftkk$1@dont-email.me>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=127062&group=sci.electronics.design#127062

  copy link   Newsgroups: sci.electronics.design
Path: i2pn2.org!i2pn.org!eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: pcdhSpam...@electrooptical.net (Phil Hobbs)
Newsgroups: sci.electronics.design
Subject: Re: Electrostatic emulsion separation [Bill Sloman]
Date: Thu, 17 Aug 2023 00:06:37 -0000 (UTC)
Organization: A noiseless patient Spider
Lines: 28
Message-ID: <ubjoad$3ftkk$1@dont-email.me>
References: <58510804-bed0-4c83-bc64-f82e050c54edn@googlegroups.com>
MIME-Version: 1.0
Content-Type: text/plain; charset=UTF-8
Content-Transfer-Encoding: 8bit
Injection-Date: Thu, 17 Aug 2023 00:06:37 -0000 (UTC)
Injection-Info: dont-email.me; posting-host="e3f607e66f8b0a10d260a608c026fc24";
logging-data="3667604"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX19ePJ1waRmPY040f8D03QCR"
User-Agent: NewsTap/5.5 (iPhone/iPod Touch)
Cancel-Lock: sha1:ID0Tf+qwcT0EOut6GT0Re7x/VOo=
sha1:MTWwhoqsdbnl0cLoognXrWBIihM=
 by: Phil Hobbs - Thu, 17 Aug 2023 00:06 UTC

Lamont Cranston <amdx62@gmail.com> wrote:
> Anyone is free to answer, I just wanted Bill look at it.
> Running tests on the 2"x2"x 34" glass vessel with aluminum tape
> electrodes on two sides. The emulsion is 23% water and 77% soybean oil.
> The first test the water was clean, we drain the unit shake the oil to
> get a new emulsion and repeat the test with some small change and run
> again, every subsequent test we get nearly the same separation in the
> same time, but the water is now cloudy/darker. My son said he has
> noticed the phenomenon before.
> Why would a first test have clean water and repeats
> with the same solution have cloudy/darker water?
> Thanks All.
>

If smaller oil droplets are slower to coalesce, you’d expect their
concentration to increase with the number of cycles, unless you allowed
enough time for the smallest ones.

Since the dielectric force goes like the volume, and the drag goes like the
area, that’s not too surprising.

Cheers

Phil Hobbs

--
Dr Philip C D Hobbs Principal Consultant ElectroOptical Innovations LLC /
Hobbs ElectroOptics Optics, Electro-optics, Photonics, Analog Electronics

Re: Electrostatic emulsion separation [Bill Sloman]

<9f9d5bfd-64ef-49d2-b275-67563ba9d3a2n@googlegroups.com>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=127064&group=sci.electronics.design#127064

  copy link   Newsgroups: sci.electronics.design
X-Received: by 2002:a05:622a:148d:b0:40f:f1ed:9841 with SMTP id t13-20020a05622a148d00b0040ff1ed9841mr37929qtx.12.1692231240805;
Wed, 16 Aug 2023 17:14:00 -0700 (PDT)
X-Received: by 2002:a05:6a00:2d16:b0:686:6ce2:f256 with SMTP id
fa22-20020a056a002d1600b006866ce2f256mr1650456pfb.2.1692231240099; Wed, 16
Aug 2023 17:14:00 -0700 (PDT)
Path: i2pn2.org!i2pn.org!weretis.net!feeder8.news.weretis.net!proxad.net!feeder1-2.proxad.net!209.85.128.88.MISMATCH!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: sci.electronics.design
Date: Wed, 16 Aug 2023 17:13:59 -0700 (PDT)
In-Reply-To: <ubjoad$3ftkk$1@dont-email.me>
Injection-Info: google-groups.googlegroups.com; posting-host=69.1.57.19; posting-account=CCHfRQoAAABYiM-2uDHkSWkyFSzTOd-m
NNTP-Posting-Host: 69.1.57.19
References: <58510804-bed0-4c83-bc64-f82e050c54edn@googlegroups.com> <ubjoad$3ftkk$1@dont-email.me>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <9f9d5bfd-64ef-49d2-b275-67563ba9d3a2n@googlegroups.com>
Subject: Re: Electrostatic emulsion separation [Bill Sloman]
From: amd...@gmail.com (Lamont Cranston)
Injection-Date: Thu, 17 Aug 2023 00:14:00 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
 by: Lamont Cranston - Thu, 17 Aug 2023 00:13 UTC

> If smaller oil droplets are slower to coalesce, you’d expect their
> concentration to increase with the number of cycles, unless you allowed
> enough time for the smallest ones.
>
> Since the dielectric force goes like the volume, and the drag goes like the
> area, that’s not too surprising.
>
> Cheers
>
> Phil Hobbs
>
> --
> Dr Philip C D Hobbs Principal Consultant ElectroOptical Innovations LLC /
> Hobbs ElectroOptics Optics, Electro-optics, Photonics, Analog Electronics

Hmm, Maybe, I'll save a portion of the next drain and let the water evaporate to see if there is an oil left.
I may also run a much longer test to see if it clears, the level of water in the vessel is real close to the proper percentage at 10 minutes,
I have let it run 20 minutes though. More fun!
Thanks for the input, Mikek

Re: Electrostatic emulsion separation [Bill Sloman]

<67b54358-d16a-4a7e-b441-02ed5c4928ean@googlegroups.com>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=127068&group=sci.electronics.design#127068

  copy link   Newsgroups: sci.electronics.design
X-Received: by 2002:a05:620a:8e8c:b0:76c:81dc:afee with SMTP id rf12-20020a05620a8e8c00b0076c81dcafeemr44736qkn.12.1692275075076;
Thu, 17 Aug 2023 05:24:35 -0700 (PDT)
X-Received: by 2002:a17:903:1d1:b0:1ae:7604:d65c with SMTP id
e17-20020a17090301d100b001ae7604d65cmr1816747plh.0.1692275074527; Thu, 17 Aug
2023 05:24:34 -0700 (PDT)
Path: i2pn2.org!i2pn.org!usenet.goja.nl.eu.org!3.eu.feeder.erje.net!feeder.erje.net!proxad.net!feeder1-2.proxad.net!209.85.160.216.MISMATCH!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: sci.electronics.design
Date: Thu, 17 Aug 2023 05:24:34 -0700 (PDT)
In-Reply-To: <7cbf020b-83a8-4b94-a81d-3686b718da86n@googlegroups.com>
Injection-Info: google-groups.googlegroups.com; posting-host=69.1.57.19; posting-account=CCHfRQoAAABYiM-2uDHkSWkyFSzTOd-m
NNTP-Posting-Host: 69.1.57.19
References: <58510804-bed0-4c83-bc64-f82e050c54edn@googlegroups.com>
<ubjoad$3ftkk$1@dont-email.me> <7cbf020b-83a8-4b94-a81d-3686b718da86n@googlegroups.com>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <67b54358-d16a-4a7e-b441-02ed5c4928ean@googlegroups.com>
Subject: Re: Electrostatic emulsion separation [Bill Sloman]
From: amd...@gmail.com (Lamont Cranston)
Injection-Date: Thu, 17 Aug 2023 12:24:35 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
 by: Lamont Cranston - Thu, 17 Aug 2023 12:24 UTC

On Thursday, August 17, 2023 at 2:16:12 AM UTC-5, Anthony William Sloman wrote:
> On Thursday, August 17, 2023 at 10:06:46 AM UTC+10, Phil Hobbs wrote:
> > Lamont Cranston <amd...@gmail.com> wrote:
> > > Anyone is free to answer, I just wanted Bill look at it.
> > > Running tests on the 2"x2"x 34" glass vessel with aluminum tape
> > > electrodes on two sides. The emulsion is 23% water and 77% soybean oil.
> > > The first test the water was clean, we drain the unit shake the oil to
> > > get a new emulsion and repeat the test with some small change and run
> > > again, every subsequent test we get nearly the same separation in the
> > > same time, but the water is now cloudy/darker. My son said he has
> > > noticed the phenomenon before.
> > > Why would a first test have clean water and repeats
> > > with the same solution have cloudy/darker water?
> > > Thanks All.
> > >
> > If smaller oil droplets are slower to coalesce, you’d expect their
> > concentration to increase with the number of cycles, unless you allowed
> > enough time for the smallest ones.
> >
> > Since the dielectric force goes like the volume, and the drag goes like the
> > area, that’s not too surprising.

> What more needs to be said? I certainly can't think of anything to add.
>
> --
> Bill Sloman, Sydney

I don't know, I have confusing results. I ran a two hour test and drained the water onto a paper towel and a piece of printer paper.
I see no hint of any oil on either paper. I did see an ever so slight increase in the clarity of the water. So maybe 2 hrs is not enough time to
remove tiny droplets, if they are there, or it is something else.
Running the numbers going from 20 minutes to 2 hrs removed an extra 1.5% of water from the oil.
At the facility their chemist can more accurately measure how much water is left in the oil.
I went from 22.5% water at 20 minutes to 23.4% water at 2 hrs. Crude measurement using a ruler, but usable for estimates.
Another item, there is a thin black line between the water and oil level they call a rag layer, I would use flock layer.
What could this layer consist of? It does get thinner in the two hour run.
Here's a picture of the layers at 20 Minutes and two hours, with an inset of the slight difference of clarity.
https://www.dropbox.com/scl/fi/ay3upu11pwz0q52qko7fg/TV-20-Minute-vs-2Hr-Mark.jpg?rlkey=xfqhtgn356c38gsjbosqwo07m&dl=0
More fun today.
Thanks, Mikek

Re: Electrostatic emulsion separation [Bill Sloman]

<c1576b5e-8957-456e-a67c-7f07c5b879d9n@googlegroups.com>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=127212&group=sci.electronics.design#127212

  copy link   Newsgroups: sci.electronics.design
X-Received: by 2002:a05:622a:15:b0:407:fb08:c448 with SMTP id x21-20020a05622a001500b00407fb08c448mr18864qtw.0.1692480688710;
Sat, 19 Aug 2023 14:31:28 -0700 (PDT)
X-Received: by 2002:a63:9dc9:0:b0:564:8375:d238 with SMTP id
i192-20020a639dc9000000b005648375d238mr493089pgd.4.1692480688210; Sat, 19 Aug
2023 14:31:28 -0700 (PDT)
Path: i2pn2.org!i2pn.org!weretis.net!feeder8.news.weretis.net!proxad.net!feeder1-2.proxad.net!209.85.160.216.MISMATCH!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: sci.electronics.design
Date: Sat, 19 Aug 2023 14:31:27 -0700 (PDT)
In-Reply-To: <67b54358-d16a-4a7e-b441-02ed5c4928ean@googlegroups.com>
Injection-Info: google-groups.googlegroups.com; posting-host=69.1.57.19; posting-account=CCHfRQoAAABYiM-2uDHkSWkyFSzTOd-m
NNTP-Posting-Host: 69.1.57.19
References: <58510804-bed0-4c83-bc64-f82e050c54edn@googlegroups.com>
<ubjoad$3ftkk$1@dont-email.me> <7cbf020b-83a8-4b94-a81d-3686b718da86n@googlegroups.com>
<67b54358-d16a-4a7e-b441-02ed5c4928ean@googlegroups.com>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <c1576b5e-8957-456e-a67c-7f07c5b879d9n@googlegroups.com>
Subject: Re: Electrostatic emulsion separation [Bill Sloman]
From: amd...@gmail.com (Lamont Cranston)
Injection-Date: Sat, 19 Aug 2023 21:31:28 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
 by: Lamont Cranston - Sat, 19 Aug 2023 21:31 UTC

On Thursday, August 17, 2023 at 7:24:39 AM UTC-5, Lamont Cranston wrote:

> > > > The first test the water was clean, we drain the unit shake the oil to
> > > > get a new emulsion and repeat the test with some small change and run
> > > > again, every subsequent test we get nearly the same separation in the
> > > > same time, but the water is now cloudy/darker. My son said he has
> > > > noticed the phenomenon before.
> > > > Why would a first test have clean water and repeats
> > > > with the same solution have cloudy/darker water?
> > > > Thanks All.

A little explanation, I have an LED light on the back side of the vessel to help the camera see
what is happening.
I let the vessel drain over night, The first test with emulsion that has been treat several times, had a clear transparent water.
The very next test the water was cloudy you could not see through it. It turns out to be a simple explanation.
There is oil left on the glass after draining, making the water seem cloudy and opaque, it is the oil on the glass that make it opaque.
When I left it over night most of the oil drained of the glass to the bottom.
Mikek

Re: Electrostatic emulsion separation [Bill Sloman]

<uc2q7a$1tpmo$1@dont-email.me>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=127362&group=sci.electronics.design#127362

  copy link   Newsgroups: sci.electronics.design
Path: i2pn2.org!i2pn.org!eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: Soph...@invalid.org (John S)
Newsgroups: sci.electronics.design
Subject: Re: Electrostatic emulsion separation [Bill Sloman]
Date: Tue, 22 Aug 2023 12:11:03 -0500
Organization: A noiseless patient Spider
Lines: 30
Message-ID: <uc2q7a$1tpmo$1@dont-email.me>
References: <58510804-bed0-4c83-bc64-f82e050c54edn@googlegroups.com>
<ubjoad$3ftkk$1@dont-email.me>
<7cbf020b-83a8-4b94-a81d-3686b718da86n@googlegroups.com>
<67b54358-d16a-4a7e-b441-02ed5c4928ean@googlegroups.com>
<c1576b5e-8957-456e-a67c-7f07c5b879d9n@googlegroups.com>
MIME-Version: 1.0
Content-Type: text/plain; charset=UTF-8; format=flowed
Content-Transfer-Encoding: 8bit
Injection-Date: Tue, 22 Aug 2023 17:11:06 -0000 (UTC)
Injection-Info: dont-email.me; posting-host="f03155f36ee3560b95a11c70bc15a2b0";
logging-data="2025176"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX18Jpr36eH1z69faw9mtdqrp"
User-Agent: Mozilla/5.0 (Windows NT 6.1; Win64; x64; rv:102.0) Gecko/20100101
Thunderbird/102.14.0
Cancel-Lock: sha1:CrTfz9fgS3AGjA0xYQ2M14E8kbs=
Content-Language: en-US
In-Reply-To: <c1576b5e-8957-456e-a67c-7f07c5b879d9n@googlegroups.com>
 by: John S - Tue, 22 Aug 2023 17:11 UTC

On 8/19/2023 4:31 PM, Lamont Cranston wrote:
> On Thursday, August 17, 2023 at 7:24:39 AM UTC-5, Lamont Cranston wrote:
>
>>>>> The first test the water was clean, we drain the unit shake the oil to
>>>>> get a new emulsion and repeat the test with some small change and run
>>>>> again, every subsequent test we get nearly the same separation in the
>>>>> same time, but the water is now cloudy/darker. My son said he has
>>>>> noticed the phenomenon before.
>>>>> Why would a first test have clean water and repeats
>>>>> with the same solution have cloudy/darker water?
>>>>> Thanks All.
>
> A little explanation, I have an LED light on the back side of the vessel to help the camera see
> what is happening.
> I let the vessel drain over night, The first test with emulsion that has been treat several times, had a clear transparent water.
> The very next test the water was cloudy you could not see through it. It turns out to be a simple explanation.
> There is oil left on the glass after draining, making the water seem cloudy and opaque, it is the oil on the glass that make it opaque.
> When I left it over night most of the oil drained of the glass to the bottom.
> Mikek

Is it safe to assume that the electrodes are on the outside, not in
contact with your emulsion?

Can you rinse the glass container with rubbing alcohol? It would have an
affinity for the oil plus water.

- John

Re: Electrostatic emulsion separation [Bill Sloman]

<9bb27d2f-a93c-41dc-8034-c64e5394177dn@googlegroups.com>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=127391&group=sci.electronics.design#127391

  copy link   Newsgroups: sci.electronics.design
X-Received: by 2002:a05:622a:19a9:b0:403:ab15:17a0 with SMTP id u41-20020a05622a19a900b00403ab1517a0mr109947qtc.12.1692753428265;
Tue, 22 Aug 2023 18:17:08 -0700 (PDT)
X-Received: by 2002:a05:6a00:10c4:b0:68a:3762:72c3 with SMTP id
d4-20020a056a0010c400b0068a376272c3mr5118909pfu.0.1692753427844; Tue, 22 Aug
2023 18:17:07 -0700 (PDT)
Path: i2pn2.org!i2pn.org!usenet.blueworldhosting.com!diablo1.usenet.blueworldhosting.com!peer02.iad!feed-me.highwinds-media.com!news.highwinds-media.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: sci.electronics.design
Date: Tue, 22 Aug 2023 18:17:07 -0700 (PDT)
In-Reply-To: <uc2q7a$1tpmo$1@dont-email.me>
Injection-Info: google-groups.googlegroups.com; posting-host=69.1.57.19; posting-account=CCHfRQoAAABYiM-2uDHkSWkyFSzTOd-m
NNTP-Posting-Host: 69.1.57.19
References: <58510804-bed0-4c83-bc64-f82e050c54edn@googlegroups.com>
<ubjoad$3ftkk$1@dont-email.me> <7cbf020b-83a8-4b94-a81d-3686b718da86n@googlegroups.com>
<67b54358-d16a-4a7e-b441-02ed5c4928ean@googlegroups.com> <c1576b5e-8957-456e-a67c-7f07c5b879d9n@googlegroups.com>
<uc2q7a$1tpmo$1@dont-email.me>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <9bb27d2f-a93c-41dc-8034-c64e5394177dn@googlegroups.com>
Subject: Re: Electrostatic emulsion separation [Bill Sloman]
From: amd...@gmail.com (Lamont Cranston)
Injection-Date: Wed, 23 Aug 2023 01:17:08 +0000
Content-Type: text/plain; charset="UTF-8"
X-Received-Bytes: 2876
 by: Lamont Cranston - Wed, 23 Aug 2023 01:17 UTC


> > I let the vessel drain over night, The first test with emulsion that has been treat several times, had a clear transparent water.
> > The very next test the water was cloudy you could not see through it. It turns out to be a simple explanation.
> > There is oil left on the glass after draining, making the water seem cloudy and opaque, it is the oil on the glass that make it opaque.
> > When I left it over night most of the oil drained of the glass to the bottom.
> > Mikek
> Is it safe to assume that the electrodes are on the outside, not in
> contact with your emulsion?
>
> Can you rinse the glass container with rubbing alcohol? It would have an
> affinity for the oil plus water.
>
> - John

At this point the clarity is not a problem, now that we know it is oil on the glass, until we figured that out
we weren't sure why the water was milky. It wasn't milky, we were just looking through a layer oil.
If you would like to see a short video, I put a dropbox link. At 10 seconds look at the top 2/3 of the tube to
see all the globules of water falling. It gets very slow after 45 seconds. Start the video over and watch all the waves
at the bottom of the tube. Without power it takes about an hour to get close to that amount of separation.
https://www.dropbox.com/scl/fi/15gcd0r1hq9p0cgev1zwn/9-TV-4KV-60-Hz-AC-transformer-8-19.mp4?rlkey=k0mwvklt6dng95l3pr9ksfpxh&dl=0
Mikek
P.S. Starting to craft ideas for a stainless steel version.

1
server_pubkey.txt

rocksolid light 0.9.8
clearnet tor