Rocksolid Light

Welcome to novaBBS (click a section below)

mail  files  register  newsreader  groups  login

Message-ID:  

The first version always gets thrown away.


tech / sci.electronics.equipment / Re: Tektronix 2467B (similar to 2465B): Error Message TEST 04 FAIL 13 (3453)

SubjectAuthor
o Re: Tektronix 2467B (similar to 2465B): Error Message TEST 04 FAIL 13 (3453)GumpyGus

1
Re: Tektronix 2467B (similar to 2465B): Error Message TEST 04 FAIL 13 (3453)

<1750a64b2801fea0$1$2230647$fd385da@news.newsgroupdirect.com>

  copy mid

https://www.novabbs.com/tech/article-flat.php?id=7&group=sci.electronics.equipment#7

  copy link   Newsgroups: sci.electronics.equipment sci.electronics.repair
From: 7dcd78c6...@example.com (GumpyGus)
Newsgroups: sci.electronics.equipment,sci.electronics.repair
Subject: Re: Tektronix 2467B (similar to 2465B): Error Message TEST 04 FAIL 13 (3453)
X-Poster: Hermes 2.0
References: <1164994618.862222.162250@79g2000cws.googlegroups.com> <iqu7n2ho0496bnd0ar659pg8k4slj80rit@4ax.com> <1165822595.159255.48440@j72g2000cwa.googlegroups.com> <1165822659.086493.110560@80g2000cwy.googlegroups.com> <1168274605.641370.172920@38g2000cwa.googlegroups.com> <1168326872.940758.126370@q40g2000cwq.googlegroups.com>
In-Reply-To: <1168326872.940758.126370@q40g2000cwq.googlegroups.com>
Content-Transfer-Encoding: 8bit
Injection-Info: 96fcc03abb98e768b714f60bc79a6345;c8b9506a8dced7c123cca02769ce15a6
Content-Type: text/plain; charset="iso-8859-1"; format="flowed"
Lines: 5
Path: i2pn2.org!i2pn.org!weretis.net!feeder8.news.weretis.net!newsreader4.netcologne.de!news.netcologne.de!peer01.ams1!peer.ams1.xlned.com!news.xlned.com!peer03.iad!feed-me.highwinds-media.com!news.highwinds-media.com!feeder.usenetexpress.com!tr2.iad1.usenetexpress.com!news.newsgroupdirect.com!not-for-mail
Date: Tue, 28 Mar 2023 17:45:02 +0000
Nntp-Posting-Date: Tue, 28 Mar 2023 17:45:02 +0000
Organization: NewsgroupDirect
X-Complaints-To: abuse@newsgroupdirect.com
Message-Id: <1750a64b2801fea0$1$2230647$fd385da@news.newsgroupdirect.com>
X-Received-Bytes: 1553
 by: GumpyGus - Tue, 28 Mar 2023 17:45 UTC

It is likely to be a run-down battery. The calibration constants are held in a CMOS RAM which needs battery voltage to hold the calibration constants.

--